• SAE ARP 5376 : 2010

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    METHODS, LOCATIONS AND CRITERIA FOR SYSTEM SAMPLING AND MEASURING THE SOLID PARTICLE CONTAMINATION OF HYDRAULIC FLUIDS

    Available format(s):  Hardcopy, PDF

    Superseded date:  11-06-2021

    Language(s):  English

    Published date:  08-03-2010

    Publisher:  SAE International

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope and field of application
    2 Applicable documents
       2.1 SAE publications
       2.2 ISO publications
    3 General cleanliness
    4 Use of solvents
    5 Filtration of solvents
       5.1 Pressure filtration
       5.2 Vacuum filtration
    6 Sample bottles
       6.1 General cleaning requirements
       6.2 Recommended cleaning procedure for sample bottles
       6.3 Checking and controlling cleaning methods
    7 Location of sampling points
    8 Sampling apparatus
       8.1 Permanent sampling connection
       8.2 On-Line sampling apparatus
       8.3 Bottle sample apparatus
    9 Bottle sampling method
    10 Sampling frequency
    11 Analysis method using an on-line automatic particle
       counter
       11.1 System operation prior to sampling and analysis
       11.2 On-line sampling and analysis procedure
       11.3 Expression of results
    12 Analysis method using an automatic particle counter
       (bottle samples)
       12.1 Principle
       12.2 Calibration of the automatic particle counter
       12.3 Procedure
       12.4 Expression of results
    13 Analysis method using a microscope (bottle samples)
       13.1 Principle
       13.2 Procedures
       13.3 Expression of results
    14 Test report
       14.1 General
       14.2 Test-report form
       14.3 Minimum data to be included in the test report
    15 Notes

    Abstract - (Show below) - (Hide below)

    Specifies procedures for assuring cleanliness of sampling equipment, for performing the sampling process, and for measuring and reporting the sample particle count.

    General Product Information - (Show below) - (Hide below)

    Committee A-6C1
    Document Type Revision
    Publisher SAE International
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    SAE AS 598 : 2012 AEROSPACE MICROSCOPIC SIZING AND COUNTING OF PARTICULATE CONTAMINATION FOR FLUID POWER SYSTEMS
    SAE ARP 598 : 2016 AEROSPACE MICROSCOPIC SIZING AND COUNTING OF PARTICULATE CONTAMINATION FOR FLUID POWER SYSTEMS
    SAE AIR 1922 : 2017 AEROSPACE - SYSTEM INTEGRATION FACTORS THAT AFFECT HYDRAULIC PUMP LIFE
    SAE ARP 4752 : 2013 AEROSPACE - DESIGN AND INSTALLATION OF COMMERCIAL TRANSPORT AIRCRAFT HYDRAULIC SYSTEMS
    SAE ARP 5891 : 2014 ACHIEVING CLEANLINESS STANDARDS FOR AIRCRAFT HYDRAULIC SYSTEMS DURING MANUFACTURE
    SAE AS 4059F : 2013 AEROSPACE FLUID POWER - CONTAMINATION CLASSIFICATION FOR HYDRAULIC FLUIDS
    09/30204130 DC : DRAFT MAY 2009 BS ISO 11217 - AEROSPACE - HYDRAULIC SYSTEM FLUID CONTAMINATION - LOCATION OF SAMPLING POINTS AND CRITERIA FOR SAMPLING
    SAE ARP 6200 : 2014 TEST REQUIREMENTS AND MEANS FOR COMMERCIAL AIRCRAFT HYDRAULIC SYSTEMS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective