• SN EN 62271-100 : AMD 1 2002

    Current The latest, up-to-date edition.

    HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 100: HIGH-VOLTAGE ALTERNATING-CURRENT CIRCUIT-BREAKERS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Swiss Standards

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 General
       1.1 Scope
       1.2 Normative references
    2 Normal and special service conditions
    3 Definitions
       3.1 General terms
       3.2 Assemblies
       3.3 Parts of assemblies
       3.4 Switching devices
       3.5 Parts of circuit-breakers
       3.6 Operation
       3.7 Characteristic quantities
       3.8 Index of definitions
    4 Ratings
       4.1 Rated voltage (U[r])
       4.2 Rated insulation level
       4.3 Rated frequency (f[r])
       4.4 Rated normal current (I[r]) and temperature
             rise
       4.5 Rated short-time withstand current (I[k])
       4.6 Rated peak withstand current (I[p])
       4.7 Rated duration of short circuit (t[k])
       4.8 Rated supply voltage of closing and opening
             devices and of auxiliary and control circuits
             (U[a])
       4.9 Rated supply frequency of closing and opening
             devices and auxiliary circuits
       4.10 Rated pressures of compressed gas supply for
             insulation, operation and/or interruption
    5 Design and construction
       5.1 Requirements for liquids in circuit-breakers
       5.2 Requirements for gases in circuit-breakers
       5.3 Earthing of circuit-breakers
       5.4 Auxiliary equipment
       5.5 Dependent power closing
       5.6 Stored energy closing
       5.7 Independent manual operation
       5.8 Operation of releases
       5.9 Low- and high-pressure interlocking devices
       5.10 Nameplates
       5.11 Interlocking devices
       5.12 Position indication
       5.13 Degrees of protection by enclosures
       5.14 Creepage distances
       5.15 Gas and vacuum tightness
       5.16 Liquid tightness
       5.17 Flammability
       5.18 Electromagnetic compatibility
    6 Type tests
       6.1 General
       6.2 Dielectric tests
       6.3 Radio interference voltage (r.i.v) tests
       6.4 Measurement of the resistance of the main
             control
       6.5 Temperature-rise tests
       6.6 Short-time withstand current and peak withstand
             current tests
       6.7 Verification of the degree of protection
       6.8 Tightness tests
       6.9 Electromagnetic compatibility (EMC) tests
       6.101 Mechanical and environmental tests
       6.102 Miscellaneous provisions for marking and
             breaking tests
       6.103 Test circuits for short-circuit making and
             breaking tests
       6.104 Short-circuit test quantities
       6.105 Short-circuit test procedure
       6.106 Basic short-circuit test-duties
       6.107 Critical current tests
       6.108 Single-phase and double-earth fault tests
       6.109 Short-line fault tests
       6.110 Out-of-phase making and breaking tests
       6.111 Capacitive current switching tests
       6.112 Special requirements for making and breaking
             tests on class E2 circuit-breakers
    7 Routine tests
       7.1 Dielectric test on the main circuit
       7.2 Dielectric test on auxiliary and control circuits
       7.3 Measurement of the resistance of the main circuit
       7.4 Tightness test
       7.5 Design and visual checks
    8 Guide to the selection of circuit-breakers for service
    9 Information to be given with enquiries, tenders and
       service
    10 Rules for transport, storage, installation, operation
       and maintenance
       10.1 Conditions during transport, storage and
             installation
       10.2 Installation
       10.3 Operation
       10.4 Maintenance
    11 Safety
    Annex A (normative) Calculation of transient recovery
            voltages for short-line faults from rated
            characteristics
    Annex B (normative) Tolerances on test quantities during
            type tests
    Annex C (normative) Records and reports of type tests
    Annex D (normative) Determination of short-circuit power
            factor
    Annex E (normative) Method of drawing the envelope of the
            prospective transient recovery voltage of a circuit
            and determining the representative parameters
    Annex F (normative) Methods of determining prospective
            transient recovery voltage waves
    Annex G (normative) Rationale behind introduction of
            circuit-breakers class E2
    Annex H (informative) Inrush currents of single and
            back-to-back capacitor banks
    Annex I (informative) Explanatory notes
    Annex J (informative) Test current and line length tolerances
            for short-line fault testing
    Annex K (informative) List of symbols and abbreviations used
            in IEC 62271-100

    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications
    Bibliography
    Figures
    Tables

    Abstract - (Show below) - (Hide below)

    Applies to a.c. circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1000 V.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Swiss Standards
    Status Current
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective