Introduction
1 Scope
2 Normative references
3 Terms, definitions, and symbols
3.1 Terms and definitions
3.2 Symbols
4 Types of corrosion
4.1 General
4.2 Uniform corrosion
4.3 Pitting corrosion
4.4 Selective corrosion
4.5 Bimetallic corrosion
5 Assessment of corrosion likelihood
Bibliography
Provides a review of influencing factors of the corrosion likelihood of hot dip galvanized steel and cast iron, used as tubes, tanks and equipment, unalloyed and low alloy ferrous materials in water distribution and storage systems as defined in EN 12502-1.
Committee |
CTN 112
|
DevelopmentNote |
Supersedes UNE 37509. (11/2005)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NBN EN 12502-3 : 2005 | Identical |
NEN EN 12502-3 : 2005 | Identical |
NS EN 12502-3 : 1ED 2005 | Identical |
I.S. EN 12502-3:2005 | Identical |
SN EN 12502-3 : 2005 | Identical |
UNI EN 12502-3 : 2005 | Identical |
BS EN 12502-3:2004 | Identical |
EN 12502-3:2004 | Identical |
NF EN 12502-3 : 2005 | Identical |
DIN EN 12502-3:2005-03 | Identical |
UNE 100003-1-1:2015 | Thermal systems of the building. Criteria for classifying the quality of thermal systems. Part 1-1: Qualification Criteria for the quality of the technical documentation. |