UNE EN 60898 : 1992 A19 2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS
01-10-2008
12-01-2013
1. General
2. Definitions
3. Classification
4. Characteristics of circuit-breakers
5. Marking and other product information
6. Standard conditions for operation in service
7. Requirements for construction and operation
8. Tests
8.1 Type tests and routine tests
8.2 Test conditions
8.3 Indelibility of marking
8.4 Reliability of screws, current-carrying parts and
connections
8.5 Reliability of terminals for external conductors
8.6 Protection against electric shock
8.7 Dielectric properties
8.8 Temperature rise and power loss
8.9 28-day test
8.10 Tripping characteristics
8.11 Mechanical and electrical
8.12 Short-circuit
8.13 Resistance to mechanical shock and impact
8.14 Resistance to heat
8.15 Resistance to abnormal heat and to fire
8.16 Resistance to rusting
Figures
A. Determination of short-circuit power factor
B. Determination of clearances and creepage distances
C. Test sequences and number of samples to be submitted
for certification purposes
D. Coordination of circuit-breakers with separate fuses
associated in the same circuit
E. Special requirements for auxiliary circuits for
safety extra-low voltage
F. Examples of terminals
G. Void
H. Arrangement for the detection of the emission of
ionized gases during short-circuit tests
ZA. Classification of circuit-breakers into energy
limiting classes
ZB. Guide for the selection of circuit breakers with
reference to their rated voltage
Applies to a.c. air break circuit breakers for operation at 50 Hz aor 60 Hz with rated voltage not exceeding 440V (between phases), a rated current not exceeding 125 A and a rated short circuit capacity not exceeding 25,000 A. These circuit breakers are designed for protection against overcurrents of wiring installations of buildings, they are for use by uninstructed people and for not being maintained. Also covers circuit breakers with more than one rated current provided that the rating cannot be changed without use of a tool.
Committee |
CTN 201
|
DevelopmentNote |
Supersedes UNE 20347. (08/2003)
|
DocumentType |
Standard
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 60898:1991/A19:2000 | Identical |
BS EN 60898:1991 | Identical |
I.S. EN 60898:1992 | Identical |
SN EN 60898 : 1991 AMD 19 2000 | Identical |
NEN EN 60898 : 1992 AMD 16 1996 | Identical |
IEC 60898:1995 | Identical |
NF EN 60898 : 92 AMD 19 2001 | Identical |
DIN EN 60898 : AMD 19 2000 | Identical |
UNE 202009-27:2016 IN | Guidelines for verification and inspection of electrical installations in locations containing a bath or shower |
UNE 202009-30:2016 IN | Guidelines for verification and inspection of low voltage electrical installations at premises with special characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.