UNE-EN IEC 60079-0:2021
Current
The latest, up-to-date edition.
Explosive atmospheres - Part 0: Equipment - General requirements
Hardcopy , PDF
20-01-2021
This part of IEC 60079 specifies the general requirements for construction, testing and
marking of equipment and Ex Components intended for use in explosive atmospheres.
The standard atmospheric conditions (relating to the explosion characteristics of the
atmosphere) under which it may be assumed that equipment can be operated are:
" temperature 20 °C to +60 °C;
" pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and
" air with normal oxygen content, typically 21 % v/v.
This standard and other standards supplementing this standard specify additional test
requirements for equipment operating outside the standard temperature range, but further
additional consideration and additional testing may be required for equipment operating
outside the standard atmospheric pressure range and standard oxygen content, particularly
with respect to types of protection that depend on quenching of a flame such as flameproof
enclosure d (IEC 60079-1) or limitation of energy, intrinsic safety i (IEC 60079-11).
NOTE 1 Although the standard atmospheric conditions above give a temperature range for the atmosphere
of -20 °C to +60 °C, the normal ambient temperature range for the equipment is 20 °C to +40 °C, unless otherwise
specified and marked. See 5.1.1. It is considered that 20 °C to +40 °C is appropriate for most equipment and that
to manufacture all equipment to be suitable for a standard atmosphere upper ambient temperature of +60 °C would
place unnecessary design constraints.
NOTE 2 Requirements given in this standard result from an ignition hazard assessment made on equipment. The
ignition sources taken into account are those found associated with this type of equipment, such as hot surfaces,
electromagnetic radiation, mechanically generated sparks, mechanical impacts resulting in thermite reactions,
electrical arcing and static electric discharge in normal industrial environments.
NOTE 3 Where an explosive gas atmosphere and a combustible dust atmosphere are, or may be, present at the
same time, the simultaneous presence of both should be considered and may require additional protective
measures. Additional guidance on the use of equipment in hybrid mixtures (mixture of a flammable gas or vapour
with a combustible dust or combustible flyings) is given in IEC 60079-14.
This standard does not specify requirements for safety, other than those directly related to the
explosion risk.
Ignition sources like adiabatic compression, shock waves, exothermic chemical reaction, self ignition of dust, naked flames and hot gases/liquids, are not addressed by this standard.
NOTE 4 Although outside the scope of this standard, such equipment would typically be subjected to a hazard
analysis that identifies and lists all of the potential sources of ignition by the equipment and the measures to be
applied to prevent them becoming effective. See ISO/IEC 80079-36.
This standard is supplemented or modified by the following standards and normative technical
Specifications:
IEC 60079-1: Gas Flameproof enclosures "d";
IEC 60079-2: Gas and dust Pressurized enclosures "p";
IEC 60079-5: Gas Powder filling "q";
IEC 60079-6: Gas Oil immersion "o";
IEC 60079-7: Gas Increased safety "e";
IEC 60079-11: Gas and dust Intrinsic safety "i";
IEC 60079-13: Gas and dust Equipment protection by pressurized room p & artificially
ventilated room v ;
- IEC 60079-15: Gas 432 Type of protection n ;
IEC 60079-18: Gas and dust Encapsulation "m";
IEC 60079-25: Gas and dust Intrinsically safe electrical systems
IEC 60079-26: Gas Equipment with equipment protection level (EPL) Ga
IEC 60079-28: Gas and dust Protection of equipment and transmission systems using
optical radiation
IEC 60079-29-1: Gas detectors Performance requirements of detectors for flammable
gases
IEC 60079-29-4: Gas detectors Performance requirements of open path detectors for
flammable gases
IEC/IEEE 60079-30-1: Gas and dust Electrical resistance trace heating General and
testing requirements.
IEC 60079-31: Dust Protection by enclosure t
IEC 60079-33: Gas and dust Special protection s
IEC 60079-35-1: Caplights for use in mines susceptible to firedamp General
requirements - Construction and testing in relation to the risk of explosion
IEC TS 60079-40: Gas - Requirements for process sealing between flammable process
fluids and electrical systems
NOTE 5 Information on explosion protection for non-electrical equipment can be found in ISO 80079-36 .
This standard with the additional standards mentioned above, are not applicable to the
construction of
" electromedical apparatus,
" shot-firing exploders,
" test devices for exploders, and
" shot-firing circuits.
| Committee |
CTN 202/SC 31
|
| DocumentType |
Standard
|
| ISBN |
978-2-8322-5065-5
|
| Pages |
159
|
| ProductNote |
THIS STANDARD IS ALSO REFERS TO: IEEE/PCIC-2002-08
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Standards | Relationship |
| IEC 60079-0:2017/COR1:2020 | Identical |
| IEC 60079-0:2017 | Identical |
| EN IEC 60079-0:2018 | Identical |
| EN IEC 60079-0:2018/AC:2020-02 | Identical |
| IEC 60079-0:2007 | Identical |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.