• Shopping Cart
    There are no items in your cart

UNE-EN ISO 5167-5:2016

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 5: Cone meters (ISO 5167-5:2016)

Available format(s)

Hardcopy , PDF

Language(s)

Spanish, Castilian, English

Published date

27-07-2016

Superseded date

27-09-2023

Superseded by

UNE-EN ISO 5167-5:2023

€82.80
Excluding VAT

This part of ISO 5167 specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. As the uncertainty of an uncalibrated cone meter may be too large for a particular application, it may be deemed essential to calibrate the flow meter in accordance with section 7 of this document. Calibrated meters shall only be used over the calibrated Reynolds number range.This part of ISO 5167 also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1.This part of ISO 5167 is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated cone meters can only be used within specified limits of pipe size, roughness, and Reynolds number. This part of ISO 5167 is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated cone meters in pipes sized less than 50 mm or more than 500 mm, or where the pipe Reynolds numbers are below 8 x 104.A cone meter is a primary device which consists of a cone-shaped restriction held concentrically in the centre of the pipe with the cone apex upstream. The design of cone meter defined in this standard has one or more upstream pressure tappings in the wall, and a downstream pressure tapping positioned in the back face of the cone with the connection to a differential pressure transmitter being a hole through the cone to the support bar, and then up through the support bar. Alternative designs of cone meters are available; however, at the time of writing there is insufficient data to fully characterise these devices, and therefore these meters shall be calibrated in accordance with Section 7.

Committee
CTN 82/SC 3
DocumentType
Standard
Pages
24
PublisherName
Asociación Española de Normalización
Status
Superseded
SupersededBy

Standards Relationship
EN ISO 5167-5:2016 Identical
ISO 5167-5:2016 Identical

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 5168:2005 Measurement of fluid flow — Procedures for the evaluation of uncertainties
ISO/TR 3313:1998 Measurement of fluid flow in closed conduits — Guidelines on the effects of flow pulsations on flow-measurement instruments
ISO/TR 9464:2008 Guidelines for the use of ISO 5167:2003
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 1: General principles and requirements
ISO 2186:2007 Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements
ISO 4006:1991 Measurement of fluid flow in closed conduits — Vocabulary and symbols
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

€82.80
Excluding VAT