UNE-EN ISO 5167-5:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 5: Cone meters (ISO 5167-5:2016)
Hardcopy , PDF
Spanish, Castilian, English
27-07-2016
27-09-2023
This part of ISO 5167 specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. As the uncertainty of an uncalibrated cone meter may be too large for a particular application, it may be deemed essential to calibrate the flow meter in accordance with section 7 of this document. Calibrated meters shall only be used over the calibrated Reynolds number range.This part of ISO 5167 also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1.This part of ISO 5167 is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated cone meters can only be used within specified limits of pipe size, roughness, and Reynolds number. This part of ISO 5167 is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated cone meters in pipes sized less than 50 mm or more than 500 mm, or where the pipe Reynolds numbers are below 8 x 104.A cone meter is a primary device which consists of a cone-shaped restriction held concentrically in the centre of the pipe with the cone apex upstream. The design of cone meter defined in this standard has one or more upstream pressure tappings in the wall, and a downstream pressure tapping positioned in the back face of the cone with the connection to a differential pressure transmitter being a hole through the cone to the support bar, and then up through the support bar. Alternative designs of cone meters are available; however, at the time of writing there is insufficient data to fully characterise these devices, and therefore these meters shall be calibrated in accordance with Section 7.
| Committee |
CTN 82/SC 3
|
| DocumentType |
Standard
|
| Pages |
24
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| EN ISO 5167-5:2016 | Identical |
| ISO 5167-5:2016 | Identical |
| ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
| ISO 5168:2005 | Measurement of fluid flow — Procedures for the evaluation of uncertainties |
| ISO/TR 3313:1998 | Measurement of fluid flow in closed conduits — Guidelines on the effects of flow pulsations on flow-measurement instruments |
| ISO/TR 9464:2008 | Guidelines for the use of ISO 5167:2003 |
| ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 1: General principles and requirements |
| ISO 2186:2007 | Fluid flow in closed conduits — Connections for pressure signal transmissions between primary and secondary elements |
| ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
| ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.