• PD CLC/TS 61643-22:2016

    Current The latest, up-to-date edition.

    Low-voltage surge protective devices Surge protective devices connected to telecommunications and signalling networks. Selection and application principles

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  30-04-2016

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Description of technologies
    5 Parameters for selection of SPDs and appropriate tests
      from IEC 61643-21
    6 Risk management
    7 Application of SPDs
    8 Multiservice surge protective devices
    9 Coordination of SPDs/ITE
    Annex A (informative) - Voltage-limiting components
    Annex B (informative) - Current-limiting components
    Annex C (informative) - Risk management
    Annex D (informative) - Transmission characteristics related
            to IT systems
    Annex E (informative) - Coordination of SPDs/ITE
    Annex F (informative) - Protection of Ethernet systems
    Annex G (informative) - EMC impact of SPDs
    Annex H (informative) - Definition of internal port (Source:
            ITU-T K.44)
    Annex I (informative) - Maintenance of SPDs for Information
            Technology
    Annex J (informative) - Earth potential rise (EPR)
    Annex K (informative) - References and examples of risk
            management based on IEC 62305-2
    Bibliography

    Abstract - (Show below) - (Hide below)

    Explains the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1000 V r.m.s. a.c. and 1500 V d.c.

    Scope - (Show below) - (Hide below)

    This part of IEC 61643 describes the principles for the selection, operation, location and coordination of SPDs connected to telecommunication and signalling networks with nominal system voltages up to 1 000 V r.m.s. a.c. and 1 500 V d.c.

    This standard also addresses SPDs that incorporate protection for signalling lines and power lines in the same enclosure (so called multiservice SPDs).

    General Product Information - (Show below) - (Hide below)

    Committee PEL/37
    Development Note Supersedes DD CLC/TS 61643-22. (05/2016)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    TS 101 524-2 : 1.1.1 TRANSMISSION AND MULTIPLEXING (TM); ACCESS TRANSMISSION SYSTEM ON METALLIC ACCESS CABLES; SYMMETRICAL SINGLE PAIR HIGH BIT RATE DIGITAL SUBSCRIBER LINE (SDSL); PART 2: TRANSCEIVER REQUIREMENTS
    IEC 61643-321:2001 Components for low-voltage surge protective devices - Part 321: Specifications for avalanche breakdown diode (ABD)
    TS 101 388 : 1.4.1 ACCESS TERMINALS TRANSMISSION AND MULTIPLEXING (ATTM); ACCESS TRANSMISSION SYSTEMS ON METALLIC ACCESS CABLES; ASYMMETRIC DIGITAL SUBSCRIBER LINE (ADSL) - EUROPEAN SPECIFIC REQUIREMENTS
    IEC 61643-12:2008 Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles
    IEEE 802.3-2012 IEEE Standard for Ethernet
    IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
    IEC 61000-6-1 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS
    ISO/IEC 11801:2002 Information technology Generic cabling for customer premises
    TS 101 524 : 1.5.1 ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); ACCESS TRANSMISSION SYSTEM ON METALLIC ACCESS CABLES; SYMMETRIC SINGLE PAIR HIGH BITRATE DIGITAL SUBSCRIBER LINE (SDSL)
    IEC 60728-2:2010 Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment
    IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
    IEC 61643-311:2013 Components for low-voltage surge protective devices - Part 311: Performance requirements and test circuits for gas discharge tubes (GDT)
    TS 101 135 : 1.5.3 TRANSMISSION AND MULTIPLEXING (TM); HIGH BIT-RATE DIGITAL SUBSCRIBER LINE (HDSL) TRANSMISSION SYSTEMS ON METALLIC LOCAL LINES; HDSL CORE SPECIFICATION AND APPLICATIONS FOR COMBINED ISDN-BA AND 2 048 KBIT/S TRANSMISSION
    IEC 62305-1:2010 Protection against lightning - Part 1: General principles
    EN 50173-1:2011 Information technology - Generic cabling systems - Part 1: General requirements
    IEEE C62.50-2012 IEEE Standard for Performance Criteria and Test Methods for Plug-in (Portable) Multiservice (Multiport) Surge-Protective Devices for Equipment Connected to a 120 V/240 V Single Phase Power Service and Metallic Conductive Communication Line(s)
    IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
    IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
    IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
    EG 201 280 : 1.1.1 DRAFT ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM) - RESISTIBILITY REQUIREMENTS FOR EQUIPMENT HAVING (A) TELECOMMUNICATION PORT(S)
    ISO/IEC 8802-5 : 1998 INFORMATION TECHNOLOGY - TELECOMMUNICATIONS AND INFORMATION EXCHANGE BETWEEN SYSTEMS - LOCAL AND METROPOLITAN AREA NETWORKS - SPECIFIC REQUIREMENTS - PART 5: TOKEN RING ACCESS METHOD AND PHYSICAL LAYER SPECIFICATIONS
    EN 50468:2009 Resistibility requirements to overvoltages and overcurrents due to lightning for equipment having telecommunication ports
    IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
    TS 102 080 : 1.4.1 TRANSMISSION AND MULTIPLEXING (TM); INTEGRATED SERVICES DIGITAL NETWORK (ISDN) BASIC RATE ACCESS; DIGITAL TRANSMISSION SYSTEM ON METALLIC LOCAL LINES
    IEC 62305-4:2010 Protection against lightning - Part 4: Electrical and electronic systems within structures
    IEC 61643-341:2001 Components for low-voltage surge protective devices - Part 341: Specification for thyristor surge suppressors (TSS)
    EN 50083-1:1993/A2:1997 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 1: SAFETY REQUIREMENTS
    IEC 61643-331:2003 Components for low-voltage surge protective devices - Part 331: Specification for metal oxide varistors (MOV)
    TS 101 524-1 : 1.1.1 TRANSMISSION AND MULTIPLEXING (TM); ACCESS TRANSMISSION SYSTEM ON METALLIC ACCESS CABLES; SYMMETRICAL SINGLE PAIR HIGH BIT RATE DIGITAL SUBSCRIBER LINE (SDSL); PART 1: FUNCTIONAL REQUIREMENTS
    IEC 62305-2:2010 Protection against lightning - Part 2: Risk management
    TS 101 270-2 : 1.2.1 TRANSMISSION AND MULTIPLEXING (TM); ACCESS TRANSMISSION SYSTEMS ON METALLIC ACCESS CABLES; VERY HIGH SPEED DIGITAL SUBSCRIBER LINE (VDSL); PART 2: TRANSCEIVER SPECIFICATION
    IEC 62305-3:2010 Protection against lightning - Part 3: Physical damage to structures and life hazard
    ISO Guide 73:2009 Risk management — Vocabulary
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective