• EN ISO 6145-10:2008

    Current The latest, up-to-date edition.

    Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 10: Permeation method (ISO 6145-10:2002)

    Available format(s): 

    Language(s): 

    Published date:  20-08-2008

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Principle
    4 Reagents and materials
    5 Apparatus
    6 Procedure
      6.1 Preliminary checks and operating conditions
      6.2 Determination of mass loss
    7 Expression of results
      7.1 Calculation
      7.2 Sources of uncertainty
      7.3 Estimation of uncertainties
      7.4 Example calculation of uncertainties
    Annex A (informative) Example of uncertainty calculation
            for a two-pan continuous weighing system
    Bibliography

    Abstract - (Show below) - (Hide below)

    This part of ISO 6145 specifies a dynamic method using permeation membranes for the preparation of calibrationgas mixtures containing component mole fractions ranging from 10−9 and 10−6. A relative expanded uncertainty of2,5 % of the component mole fraction can be achieved using this method. In the mole fraction range considered, itis difficult to maintain some gas mixtures, for example in cylinders, in a stable state. It is therefore desirable toprepare the calibration gas immediately before use, and to transfer it by the shortest possible path to the placewhere it is to be used. This technique has been successfully applied in generating low content calibration gasmixtures of, for example, sulfur dioxide (SO2), nitrogen dioxide (NO2) and benzene (C6H6) in air.If the carrier gas flow is measured as a gas mass-flow, the preparation of calibration gas mixtures using permeationtubes is a dynamic-gravimetric method which gives contents in mole fractions.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 238
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    DIN EN 14212 E : 2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF SULPHUR DIOXIDE BY ULTRAVIOLET FLUORESCENCE
    I.S. EN 838:2010 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS
    EN 1076:2009 Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods
    BS EN 60079-29-1:2007 Explosive atmospheres Gas detectors. Performance requirements of detectors for flammable gases
    UNE-EN 60079-29-1:2017 Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases
    DIN EN 1076:2010-04 Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods
    DIN EN 14211 E : 2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF NITROGEN DIOXIDE AND NITROGEN MONOXIDE BY CHEMILUMINESCENCE
    DIN EN 14212:2012-11 Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence
    DIN EN 14211:2012-11 Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
    DIN EN 14662-3:2016-02 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF BENZENE CONCENTRATIONS - PART 3: AUTOMATED PUMPED SAMPLING WITH IN SITU GAS CHROMATOGRAPHY
    BS EN 14211:2012 Ambient air. Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
    UNE-EN 14662-3:2016 Ambient air - Standard method for the measurement of benzene concentrations - Part 3: Automated pumped sampling with in situ gas chromatography
    I.S. EN 14211:2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF NITROGEN DIOXIDE AND NITROGEN MONOXIDE BY CHEMILUMINESCENCE
    I.S. EN 14212:2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF SULPHUR DIOXIDE BY ULTRAVIOLET FLUORESCENCE
    I.S. EN 14662-3:2015 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF BENZENE CONCENTRATIONS - PART 3: AUTOMATED PUMPED SAMPLING WITH IN SITU GAS CHROMATOGRAPHY
    VDI 2100 Blatt 3:2011-10 Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Active sampling by accumulation on adsorbents - Thermal desorption
    BS EN 1076:2009 Workplace exposure. Procedures for measuring gases and vapours using pumped samplers. Requirements and test methods
    EN 14662-3:2015 Ambient air - Standard method for the measurement of benzene concentrations - Part 3: Automated pumped sampling with in situ gas chromatography
    UNI EN 1076 : 2010 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING PUMPED SAMPLERS - REQUIREMENTS AND TEST METHODS
    UNI EN 14211 : 2012 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF NITROGEN DIOXIDE AND NITROGEN MONOXIDE BY CHEMILUMINESCENCE
    UNI EN 838 : 2010 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING DIFFUSIVE SAMPLERS - REQUIREMENTS AND TEST METHODS
    DIN EN 838:2010-05 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
    BS EN 14662-3:2015 Ambient air. Standard method for the measurement of benzene concentrations Automated pumped sampling with in situ gas chromatography
    UNE-EN 14211:2013 Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
    BS EN 838:2010 Workplace exposure. Procedures for measuring gases and vapours using diffusive samplers. Requirements and test methods
    UNE-EN 14212:2013 Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence
    I.S. EN 1076:2009 WORKPLACE EXPOSURE - PROCEDURES FOR MEASURING GASES AND VAPOURS USING PUMPED SAMPLERS - REQUIREMENTS AND TEST METHODS
    EN 14212:2012/AC:2014 AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF SULPHUR DIOXIDE BY ULTRAVIOLET FLUORESCENCE
    EN 14211:2012 Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
    EN 838:2010 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
    BS EN 14212:2012 Ambient air. Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC Guide 98:1993 Guide to the expression of uncertainty in measurement (GUM)
    ISO 7504:2015 Gas analysis Vocabulary
    ISO 6145-1:2003 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective