• EN 14211:2012

    Current The latest, up-to-date edition.

    Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence

    Available format(s): 

    Language(s): 

    Published date:  22-08-2012

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Abbreviated terms
    5 Principle
    6 Sampling
    7 Analyser equipment
    8 Type approval of nitrogen dioxide and nitrogen
       monoxide analysers
    9 Field operation and ongoing quality control
    10 Expression of results
    11 Test reports and documentation
    Annex A (normative) - Test of lack of fit
    Annex B (informative) - Sampling equipment
    Annex C (informative) - Types of chemiluminescence
            analysers
    Annex D (informative) - Manifold testing
    Annex E (normative) - Type approval
    Annex F (informative) - Calculation of uncertainty in field
            operation at the hourly limit value
    Annex G (informative) - Calculation of uncertainty in field
            operation at the annual limit value
    Annex H (informative) - Significant technical changes
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard specifies a continuous measurement method for the determination of the concentrations of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air up to 500 µg/m3. This concentration range represents the certification range for NO2 for the type approval test.The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air up to 1 200 µg/m3. This concentration range represents the certification range for NO for the type approval test.NOTE 1It is possible to use other ranges depending on the levels present in ambient air. NOTE 2When this European Standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources. The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).NOTE 3500 µg/m3 of NO2 corresponds to 261 nmol/mol of NO2 at 20 °C and 101,3 kPa. 1 200 µg/m3 of NO corresponds to 962 nmol/mol of NO at 20 °C and 101,3 kPa.This standard contains information for different groups of users.Clauses 5 to 7 and Annexes B and C contain general information about the principles of NOx measurement by chemiluminescence analyser and sampling equipment.Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of NOx analysers. These sections contain information about:-Type-approval test conditions, test procedures and test requirements;-Analyser performance requirements;-Evaluation of the type-approval test results;-Evaluation of the uncertainty of the measurement results of the NOx analyser based on the type-approval test results.Clauses 9 to 11 and Annexes F and G are directed towards monitoring networks performing the practical measurements of NOx in ambient air. These sections contain information about:-Initial installation of the analyser in the monitoring network and acceptance testing;-Ongoing quality assurance/quality control;-Calculation and reporting of measurement results;-Evaluation of the uncertainty of measurement results under practical monitoring conditions.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 264
    Development Note Supersedes PREN 14211. (09/2012)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    15/30314070 DC : 0 BS EN 16450 - AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
    DIN EN 16738 E : 2016 EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS
    I.S. EN 16339:2013 AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING
    I.S. EN 16738:2015 EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS
    I.S. EN 16450:2017 AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
    UNI EN 15267-1 : 2009 AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 1: GENERAL PRINCIPLES
    ONORM EN 15267-1 : 2009 AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 1: GENERAL PRINCIPLES
    PD CEN/TS 16450:2013 Ambient air. Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
    BS EN 16738:2015 Emission safety of combustible air fresheners. Test methods
    UNI CEN/TS 16450 : 2013 AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
    BS EN 16450:2017 Ambient air. Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
    DIN EN 16450 E : 2017 AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
    VDI 2119:2013-06 Ambient air measurements - Sampling of atmospheric particles > 2,5 ?m on an acceptor surface using the Sigma-2 passive sampler - Characterisation by optical microscopy and calculation of number settling rate and mass concentration
    UNE-EN 16450:2017 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
    14/30298789 DC : 0 BS EN 16738 - EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS
    DIN EN 16339:2013-11 Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling
    UNE-EN 16339:2014 Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling
    UNE-EN 16738:2016 Emission safety of combustible air fresheners - Test methods
    BS EN 16339:2013 Ambient air. Method for the determination of the concentration of nitrogen dioxide by diffusive sampling
    DIN EN 16738:2016-04 EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS
    I.S. EN 15267-1:2009 AIR QUALITY - CERTIFICATION OF AUTOMATED MEASURING SYSTEMS - PART 1: GENERAL PRINCIPLES
    PREN 16738 : DRAFT 2014 EMISSION SAFETY OF COMBUSTIBLE AIR FRESHENERS - TEST METHODS
    EN 16738:2015 Emission safety of combustible air fresheners - Test methods
    EN 16339:2013 Ambient air - Method for the determination of the concentration of nitrogen dioxide by diffusive sampling
    EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
    S.R. CEN/TS 16450:2013 AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
    UNI EN 16339 : 2013 AMBIENT AIR - METHOD FOR THE DETERMINATION OF THE CONCENTRATION OF NITROGEN DIOXIDE BY DIFFUSIVE SAMPLING
    BS EN 15267-1:2009 Air quality. Certification of automated measuring systems General principles
    DIN EN 15267-1:2009-07 Air quality - Certification of automated measuring systems - Part 1: General principles
    DIN EN 16450:2015-10 (Draft) AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
    EN 16450:2017 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
    CEN/TS 16450:2013 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    ISO 6144:2003 Gas analysis Preparation of calibration gas mixtures Static volumetric method
    EN ISO 6142:2006 Gas analysis - Preparation of calibration gas mixtures - Gravimetric method (ISO 6142:2001)
    ISO 6145-7:2009 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 7: Thermal mass-flow controllers
    ISO 14956:2002 Air quality Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
    EN ISO 6145-7:2010 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 7: Thermal mass-flow controllers (ISO 6145-7:2009)
    EN ISO 6143:2006 Gas analysis - Comparison methods for determining and checking the composition of calibration gas mixtures (ISO 6143:2001)
    EN 15267-2:2009 Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process
    EN ISO 6145-10:2008 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 10: Permeation method (ISO 6145-10:2002)
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    EN ISO 20988:2007 Air quality - Guidelines for estimating measurement uncertainty (ISO 20988:2007)
    ISO 6143:2001 Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    EN ISO 14956 : 2002 AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY
    ISO 6142:2001 Gas analysis Preparation of calibration gas mixtures Gravimetric method
    ISO 6145-10:2002 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 10: Permeation method
    ISO 9001:2015 Quality management systems — Requirements
    ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
    VDI 2453 Blatt 2:2002-10 Gaseous air pollution measurement - Measurement of concentration of nitrogen monoxide and nitrogen dioxide - Calibration of NO/NO chemiluminescence analysers using gas phase titration
    ISO 15337:2009 Ambient air Gas phase titration Calibration of analysers for ozone
    EN ISO 6145-6:2017 Gas analysis - Preparation of calibration gas mixtures using dynamic methods - Part 6: Critical flow orifices (ISO 6145-6:2017)
    ISO 20988:2007 Air quality Guidelines for estimating measurement uncertainty
    ISO 6145-6:2017 Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices
    EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
    EN ISO 6144:2006 Gas analysis - Preparation of calibration gas mixtures - Static volumetric method (ISO 6144:2003)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective