• I.S. EN 1366-9:2008

    Current The latest, up-to-date edition.

    FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 9: SINGLE COMPARTMENT SMOKE EXTRACTION DUCTS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2008

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Test equipment
       4.1 General
       4.2 Furnace
       4.3 Perforated plate
       4.4 Inlet nozzles (fire test)
       4.5 Ambient leakage measuring device
       4.6 Pressure sensors for differential pressure control
       4.7 Welded connecting tube
       4.8 Extract fan connecting duct
       4.9 Extraction fan
       4.10 Thermocouples
       4.11 Oxygen measuring equipment
       4.12 Restraint equipment
       4.13 Observation window
    5 Test conditions
       5.1 Differential pressure conditions
       5.2 Heating conditions
    6 Test specimen
       6.1 Size
            6.1.1 Length
            6.1.2 Cross-section
       6.2 Number
       6.3 Design
    7 Installation of test specimen
       7.1 General
       7.2 Standard supporting construction
       7.3 Duct arrangement
       7.4 Restraint of ducts
       7.5 Perforated plate
    8 Conditioning
       8.1 General
    9 Application of instrumentation
       9.1 Thermocouples
            9.1.1 Furnace thermocouples (plate thermometers)
            9.1.2 Gas temperature within flow nozzles
       9.2 Pressure
       9.3 Oxygen measurements
       9.4 Observations of reduction of cross-section
    10 Test procedure
       10.1 Pre-test calibration
            10.1.1 Oxygen-measuring instrument
            10.1.2 Perforated plate
       10.2 Leakage measurement at ambient temperature
       10.3 Fire test
            10.3.1 Extraction fan
            10.3.2 Ignition of furnace
            10.3.3 Furnace conditions
            10.3.4 Temperatures and pressures
            10.3.5 Oxygen measurements
            10.3.6 General observations
            10.3.7 Reduction of cross-section
            10.3.8 Leakage calculations
            10.3.9 Termination of test
    11 Performance criteria
       11.1 General requirements
       11.2 Criteria at ambient temperature
       11.3 Criteria under fire conditions
            11.3.1 General
            11.3.2 Leakage
            11.3.3 Reduction in cross-section
            11.3.4 Mechanical stability
    12 Test report
    13 Direct field of application of test results
       13.1 General
       13.2 Duct sizes
       13.3 Hangers
       13.4 Pressure difference
       13.5 Number of sides of duct
    Annex A (informative) - Measurement of volume/mass flow
          A.1 Hints on measuring volume flow or mass flow
              with differential pressure devices
          A.2 Density
          A.3 Absolute Pressure (barometric pressure)
          A.4 Viscosity
          A.5 Characteristic data of the inlet nozzles
              according to Figure 10
    Annex B (informative) - Measurement of oxygen content
    Annex C (informative) - The usage of correction factors for
                            the consideration of different parameters
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines a test method for determining the fire resistance of smoke extraction ducts that are used for single compartment applications only.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 1507:2006 Ventilation for buildings - Sheet metal air ducts with rectangular section - Requirements for strength and leakage
    ISO 10294-3:1999 Fire resistance tests Fire dampers for air distribution systems Part 3: Guidance on the test method
    ISO 13943:2017 Fire safety — Vocabulary
    EN 1366-1:2014 Fire resistance tests for service installations - Part 1: Ventilation ducts
    EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
    ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
    EN 1366-8:2004 Fire resistance tests for service installations - Part 8: Smoke extraction ducts
    EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
    EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
    EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
    EN 1751:2014 Ventilation for buildings - Air terminal devices - Aerodynamic testing of damper and valves
    ISO 5221:1984 Air distribution and air diffusion Rules to methods of measuring air flow rate in an air handling duct
    EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
    IEC 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective