• PREN 50200 : DRAFT 2013

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    METHOD OF TEST FOR RESISTANCE TO FIRE OF UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS

    Available format(s): 

    Superseded date:  01-12-2015

    Language(s): 

    Published date:  19-06-2013

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Test environment
    5 Test apparatus
    6 Verification procedure for source of heat
    7 Test sample (Electric power and control cables with rated
       voltage up to and including 600/1000 V)
    8 Cable test procedure (Electric power and control cables
       with rated voltage up to and including 600/1000 V)
    9 Test report (Electric power and control cables with rated
       voltage up to and including 600/1000V)
    10 Bibliography
    Annex A (Informative) - Guidance on the choice of recommended
            test equipment
    Annex B (spare)
    Annex C (Normative) - Fuse characteristic curve
    Annex D (Informative) - Guidance for classification of a range of
            power and control cables
    Annex E (Informative) - Guidance for using optional water spray
            protocol

    Abstract - (Show below) - (Hide below)

    Defines the test method for cables designed to have intrinsic resistance to fire and intended for use as emergency circuits for alarm, lighting and communication purposes.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee TC 20
    Document Type Draft
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    National Adoptions - (Show below) - (Hide below)

    Equivalent Standard(s) Relationship
    13/30282376 DC : 0 Identical

    Standards Referencing This Book - (Show below) - (Hide below)

    PREN 50582 : DRAFT 2012 METHOD OF TEST FOR RESISTANCE TO FIRE OF UNPROTECTED OPTICAL FIBRE CABLES FOR USE IN EMERGENCY CIRCUITS (DIAMETER LESS THAN OR EQUAL TO 20 MM)
    EN 50289-4-16:2016 Communication cables - Specifications for test methods - Part 4-16: Environmental test methods - Circuit integrity under fire conditions
    ISO 13943:2017 Fire safety — Vocabulary
    EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
    EN 60584-1:2013 Thermocouples - Part 1: EMF specifications and tolerances
    EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
    EN 61034-1:2005/A1:2014 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 1: TEST APPARATUS (IEC 61034-1:2005/A1:2013)
    HD 60269-3:2010/A1:2013 LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective