EN 50200:2015

Current

Current

The latest, up-to-date edition.

Method of test for resistance to fire of unprotected small cables for use in emergency circuits

Published date

04-12-2015

Sorry this product is not available in your region.
Summarise this standard

European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Test environment
5 Test apparatus
6 Verification procedure for source of heat
7 Test sample (Electric power and control
  cables with rated voltage up to and including
  600 V/1000 V)
8 Cable test procedure (Electric power and
  control cables with rated voltage up to and
  including 600 V/1000 V)
9 Test report (Electric power and control cables
  with rated voltage up to and including
  600 V/1000 V)
Annex A (informative) - Guidance on the choice of
        recommended test equipment
Annex B (normative) - Field of direct application
        and extended application of test results
        (Electric power and control cables with
        rated voltage up to and including
        600 V/1000 V)
Annex C (normative) - Fuse characteristic curve
Annex D (informative) - Information regarding
        classification
Annex E (informative) - Guidance for using optional
        water spray protocol
Bibliography

This European Standard specifies the test method for cables designed to have intrinsic resistance to fire and intended for use as emergency circuits for alarm, lighting and communication purposes.This European Standard is applicable to cables for emergency circuits of rated voltage not exceeding 600 V/1 000 V, including those of rated voltage below 80 V and optical fibre cables.This European Standard includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1 000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to copper data and telecom cables and optical cables are given in the relevant standards of CLC/TC 46X and CLC/TC 86A.The test method is limited to cables with an overall diameter not exceeding 20 mm.The test method is based on the direct impingement of flame from a propane burner giving a constant temperature attack of a notional 842 °C. It is intended to be used for cables for emergency circuits suitable for alarm, emergency lighting and communication. NOTEWhen the test method is used in support of EN 13501-3, it only applies to cables of less than 20 mm diameter, and, for metallic conductor cables, to those with conductor sizes up to and including 2,5 mm². For optical cables, only the less than 20 mm diameter limit applies.This European Standard includes (Annex B) the field of direct application and rules for extended application of test results (EXAP). Details regarding classification using data from this test are given in EN 13501-3 . Information regarding classification is given in Annex D.This European Standard also includes informative guidance (Annex E) on a means of applying a water spray to the cable during the test. Such a requirement may be a feature of particular product standards.

Committee
CLC/TC 20
DevelopmentNote
Supersedes PREN 50200. (12/2015)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

Standards Relationship
I.S. EN 50200:2015 Identical
NEN EN 50200 : 2015 Identical
CEI EN 50200 : 2016 Identical
PN EN 50200 : 2016 Identical
SS-EN 50200 : 2016 Identical
BS EN 50200:2015 Identical
NBN EN 50200 : 2016 Identical
NF EN 50200 : 2016 Identical
DIN EN 50200:2016-07 Identical
VDE 0482-200:2016-07 Identical
UNE-EN 50200:2016 Identical