(INACTIVE RECORD)IEEE 398 : 1972
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
PHOTOMULTIPLIERS FOR SCINTILLATION COUNTING AND GLOSSARY FOR SCINTILLATION COUNTING FIELD, TEST PROCEDURES FOR
17-10-2023
01-01-1972
1 General
1.1 The scintillation counter
1.2 The Cerenkov counter
2 Photomultiplier characteristics
2.1 General characteristics
2.2 Additional characteristics specific to
scintillation and Cerenkov counters
3 Testing of photomultiplier characteristics
3.1 Pulse-height characteristics
3.1.1 Pulse height
3.1.2 Pulse-height resolution
3.1.3 Pulse-height-stability measurements
3.1.4 Pulse-height linearity
3.2 Spurious-pulse characteristics
3.2.1 Dark pulses
3.2.2 Afterpulses
3.2.3 Tube scintillation pulses
3.3 Pulse timing characteristics
3.3.1 Light-emitting diodes
3.3.2 Spark light sources
3.3.3 Cerenkov source
3.3.4 Scintillator light source
3.3.5 Mode-locked laser
3.4 Measurement techniques
3.4.1 Rise-time measurements
3.4.1.1 Device rise time
3.4.1.2 Reflected-pulse rise time
3.4.1.3 Single-electron rise time
3.4.2 Fall-time measurements
3.4.3 Transit-time measurements
3.4.3.1 Device transit time
3.4.3.2 Photocathode transit time
3.4.3.3 Multiplier transit time
3.4.3.4 Output-structure transit time
3.4.4 Photocathode transit-time-difference
measurements
3.4.5 Transit-time-spread measurements
4 Test conditions for photomultipliers
5 Test instrumentation
6 Glossary for scintillation counting field
Figures
1 Cs isotope 137 equivalent LED spectrum
2 Typical electron resolution of photomultiplier
tube incorporating GaP first dynode
3 Pulse-height linearity
4 LED circuitry
5 Single-electron rise time
6 Photomultiplier transit-time measurements
7 Transit-time spread
8 Single-photoelectron time resolution
9 Scintillator photon distribution
The photomultiplier is an essential component in scintillation and Cerenkov counting. In these applications there are special requirements with regard to pulse-height characteristics, spurious pulses and timing.
DevelopmentNote |
Supersedes IEEE 175. (06/2013)
|
DocumentType |
Standard
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Withdrawn
|
IEEE DRAFT N42.15 : D2 OCT 96 | VERIFICATION OF LIQUID-SCINTILLATION COUNTING SYSTEMS |
IEEE N42.15-1997 | American National Standard Check Sources for and Verification of Liquid-Scintillation Counting Systems |
IEEE/ANSI N42.4-1971 | American National Standard for High Voltage Connectors for Nuclear Instruments |
API 551 : 2016 | PROCESS MEASUREMENT |
IEEE 279-1971 | IEEE Standard: Criteria for Protection Systems for Nuclear Power Generating Stations |
IEEE 1205-2014 | IEEE Guide for Assessing, Monitoring, and Mitigating Aging Effects on Electrical Equipment Used in Nuclear Power Generating Stations and Other Nuclear Facilities |
ANSI N13.4 : 71(R1983) | PORTABLE X-OR GAMMA RADIATION SURVEY INSTRUMENTS, SPECIFICATION OF, |
IEEE N42.12-1994 | American National Standard Calibration and Usage of Thallium-Activated Sodium Iodide Detector Systems for Assay of Radionuclides |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.