Foreword
0 Introduction
3 Definitions
5 Lift well
5.3.3 Strength of the ceiling
6 Machine and pulley rooms
6 Machinery and pulley spaces
6.1 General provisions
6.2 Access
6.3 Machine rooms
6.3.1 General provisions
6.3.2 Mechanical strength, floor surface
6.3.3 Dimensions
6.3.4 Doors and trap doors
6.3.5 Other openings
6.3.6 Ventilation
6.3.7 Lighting and socket outlets
6.3.8 Handling of equipment
6.4 Machinery inside the well
6.4.1 General provisions
6.4.2 Dimensions of working areas inside the well
6.4.3 Working areas in the car or on the car roof
6.4.4 Working areas in the pit
6.4.5 Working areas on a platform
6.4.6 Working areas outside of the well
6.4.7 Doors and traps
6.4.8 Ventilation
6.4.9 Lighting and socket outlet
6.4.10 Handling of equipment
6.5 Machinery outside of the well
6.5.1 General provisions
6.5.2 Machinery cabinet
6.5.3 Working area
6.5.4 Ventilation
6.5.5 Lighting and socket outlets
6.6 Devices for emergency and test operations
6.7 Construction and equipment of pulley spaces
6.7.1 Pulley rooms
6.7.2 Pulleys in the well
12.5 Emergency operation
13 Electric installations and appliances
13.1 General provisions
13.4 Main switches
13.6 Lighting and socket outlets
14.2.2 Stopping devices
14.2.3 Emergency alarm device
15.4 Machinery and pulley rooms
15.4 Machinery and pulley spaces
15.5 Well 19
16.3.1 Normal use
Annex A (normative) List of the electric safety devices
Annex C (Informative) Technical dossier
C.2 General
C.3 Technical details and plans
Annex D (normative) Examinations and tests before putting into service
D.2 Tests and verifications
Annex E (informative) Periodical examinations and tests, examinations
and tests after an modification or after an accident
E.2 Examinations and tests after and important modification
or after an accident
Annex ZA (informative) Clauses of this standard addressing
essential requirements or other provisions of EU Directives