5.1 General
5.2 Adjustments at the calibration check
     frequency
5.3 Other adjustments and corrections to
     indicated levels
5.4 Directional response
5.5 Frequency weightings
5.6 Level linearity
5.7 Self-generated noise
5.8 Time weightings F and S
5.9 Toneburst response
5.10 Response to repeated tonebursts
5.11 Overload indication
5.12 Under-range indication
5.13 C-weighted peak sound level
5.14 Reset
5.15 Thresholds
5.16 Display
5.17 Analogue or digital output
5.18 Timing facilities
5.19 Radio frequency emissions and disturbances
     to a public power supply
5.20 Crosstalk
5.21 Power supply
6.1 General
6.2 Static pressure
6.3 Air temperature
6.4 Humidity
6.5 Electrostatic discharge
6.6 AC power-frequency and radio-frequency fields
C.1 Introduction
C.2 Frequency weighting C
C.3 Frequency weighting A
C.4 Pole frequencies and normalization constants
C.5 Frequency weighting Z

BS EN 61672-1 ED.2

Committee
EPL/29
DocumentType
Draft
Pages
41
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

IEC 61183:1994 Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters
ISO/TR 25417:2007 Acoustics Definitions of basic quantities and terms
IEC 60942:2003 Electroacoustics - Sound calibrators
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61094-6:2004 Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
IEC 62585:2012 Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter
CISPR 16-1:1999+AMD1:2002 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)