10/30210015 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 60099-5 - SURGE ARRESTERS - SELECTION AND APPLICATION RECOMMENDATIONS
Hardcopy , PDF
30-09-2013
English
Section 1 - General
Section 2 - Surge arrester fundamentals and
applications issues
Section 3 - Insulation Co-ordination and Surge
Arrester Applications
Section 4 - Surge arresters for special applications
Section 5 - Asset management of surge arresters
Annex A (Informative) - Determination of temporary
overvoltages due to earth faults
Annex B (Informative) - Current practice
Annex C (Informative) - Arrester modelling techniques
for studies involving insulation
co-ordination and energy requirements
Annex D (Informative) - Diagnostic indicators of
metal-oxide surge arresters in service
Annex E (Informative) - Typical data needed from
arrester manufacturers for proper
selection of surge arresters
Annex F (Informative) - Glossery
Annex G (Informative) - Bibliography
Annex H (Informative) - End of life and replacement
of old gapped SiC-arresters
BS EN 60099-5
Committee |
PEL/37
|
DocumentType |
Draft
|
Pages |
131
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC TR 60071-4:2004 | Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
IEC 60099-6:2002 | Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 60099-8:2017 | Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.