11/30227728 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 60601-2-65 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-65: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF DENTAL INTRA-ORAL X-RAY EQUIPMENT
Hardcopy , PDF
31-07-2013
English
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME
EQUIPMENT
201.6 Classification of ME EQUIPMENT and
ME SYSTEMS
201.7 ME EQUIPMENT identification, marking
and documents
201.8 Protection against electrical HAZARDS
201.9 Protection against mechanical hazards of ME
EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
radiation HAZARDS
201.11 Protection against excessive temperatures
and other HAZARDS
201.12 Accuracy of controls and instruments and
protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault
conditions
201.14 PROGRAMMABLE ELECTRICAL
MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME
EQUIPMENT
202 Electromagnetic compatibility - Requirements
and tests
203 Medical electrical equipment - Part 1: General
requirements for safety - 3
Annex C (informative) - Guide to marking and labelling
requirements for ME EQUIPMENT and ME
SYSTEMS
Annex AA (informative) - Particular guidance and
rationale
Annex BB (informative) - Identification of parts of
dental X-ray intra-oral systems in relation
to defined terms in this standard
Bibliography
Index of defined terms used in this particular standard
BS EN 60601-2-65
Committee |
CH/62/2
|
DocumentType |
Draft
|
Pages |
45
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
IEC 60336:2005 | Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60601-1-3:2008+AMD1:2013 CSV | Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.