12/30254626 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PD 6693-1 - RECOMMENDATIONS FOR THE DESIGN OF STRUCTURES TO BS EN 1995 EUROCODE 5 FOR TIMBER STRUCTURES (REVISION OF BS 5268)
Hardcopy , PDF
31-10-2012
English
Introduction
1 Scope
2 Normative references
3 Terms and definitions and abbreviations
4 Design responsibilities
5 Effective anchorages for buildings of Consequence
Class 2a
6 Assignment of temperate hardwoods to BS EN 338
strength classes [BS EN 1995-1-1:2004+A1:2008, 3.2]
7 Horizontally glued laminated hardwood members
[BS EN 1995-1-1:2004+A1:2008, 3.3]
8 Factor, k[c,90,] for compression perpendicular to
grain [BS EN 1995-1-1:2004+A1:2008, 6.1.5]
9 Effective lengths of compression members
[BS EN 1995-1-1:2004+A1:2008, 6.3.2]
10 Limits on notches and circular holes in joists for
which no calculations are required
[BS EN 1995-1-1:2004+A1:2008, 6.5.1]
11 Beams with circular holes
12 Yield moment of annular ring-shanked nails
[BS EN 1995-1-1:2004+A1:2008, 8.3.1.1(4)]
13 Diameters for evaluating lateral load-carrying
capacities of screws [BS EN 1995-1-1:2004+A1:2008,
8.7.1]
14 Axially loaded screws [BS EN 1995-1-1:2004+A1:2008,
8.7.2]
15 Connections made with punched metal plate fastener
joints [BS EN 1995-1-1:2004+A1:2008, 8.8.1]
16 Misalignment tolerances in punched metal plate
fastener joints [BS EN 1995-1-1:2004+A1:2008, 8.8.5.1]
17 Contact pressure between timber members in punched
metal plate fastener joints under compression
[BS EN 1995-1-1:2004+A1:2008, 8.8.5.1(3)]
18 Trusses with punched metal plate fasteners
[BS EN 1995-1-1:2004+A1:2008, 9.2.2]
19 Masonry shielding to wall diaphragms
20 Simplified analysis of wall diaphragms
[BS EN 1995-1-1:2004+A1:2008, 9.2.4.3]
21 Contribution of plasterboard to racking resistance
22 Evaluation of design racking resistance of
plasterboard-clad timber frame walls
23 Bracing to trussed rafter roofs
[BS EN 1995-1-1:2004+A1:2008, 9.2.5.3]
24 Lateral load-carrying capacity of glued lap joints
[BS EN 1995-1-1:2004+A1:2008, 10.3]
Annexes
Annex A (normative) - Exchange of information
between building designer and component
designer(s)
Annex B (informative) - Effective anchorage of floors
to timber frame wall buildings of Consequence
Class 2a
Annex C (informative) - Actions and combinations of
actions that may be considered in the design
of trussed rafters
Annex D (informative) - Masonry shielding to timber
frame wall diaphragms
Annex E (normative) - Bracing of trussed rafter roofs
Annex F (informative) - Optional recommendations for
the support of water tanks in trussed rafter
roofs
Bibliography
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.