12/30259213 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 14181 - STATIONARY SOURCE EMISSIONS - QUALITY ASSURANCE OF AUTOMATED MEASURING SYSTEMS
Hardcopy , PDF
English
30-11-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Calibration and validation of the AMS
(QAL2)
7 Ongoing quality assurance during operation
(QAL3)
8 Annual Surveillance Test (AST)
9 Documentation
Annex A (normative) - QAL2 and AST functional test
of AMS
Annex B (normative) - Test of linearity
Annex C (informative) - Control Charts
Annex D (informative) - Documentation
Annex E (informative) - Example of calculation of the
calibration function and of the variability test
Annex F (informative) - Example of calculation of the
standard deviation s[AMS] of the AMS at zero
and span level
Annex G (informative) - Example of using the calibration
function and the variability test in the AST
Annex H (informative) - CUSUM charts field form (drift)
Annex I (informative) - Implementation of QAL1
Annex J (normative) - k[v] and t[0,95] values
Annex K (informative) - Significant technical changes
Bibliography
BS EN 14181
| Committee |
EH/2/1
|
| DocumentType |
Draft
|
| Pages |
85
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| PREN 14181 : DRAFT 2012 | Identical |
| ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
| EN 15267-3:2007 | Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources |
| CEN/TR 15983:2010 | Stationary source emissions - Guidance on the application of EN 14181:2004 |
| ISO 14956:2002 | Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty |
| EN 15267-2:2009 | Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process |
| ISO 11095:1996 | Linear calibration using reference materials |
| EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
| EN 13284-1:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method |
| EN 13284-2:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 2: Quality assurance of automated measuring systems |
| EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
| ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
| EN 14385:2004 | Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, TI and V |
| EN 14792:2017 | Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: chemiluminescence |
| EN 15267-1:2009 | Air quality - Certification of automated measuring systems - Part 1: General principles |
| ISO 3534-1:2006 | Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.