• Shopping Cart
    There are no items in your cart

16/30319034 DC : 0

NA

NA

Status of Standard is Unknown

BS EN 60601-2-2 ED 6.0 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-2: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HIGH FREQUENCY SURGICAL EQUIPMENT AND HIGH FREQUENCY SURGICAL ACCESSORIES

Available format(s)

Hardcopy , PDF

Language(s)

English

€23.37
Excluding VAT

201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME
       EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and
       documents
201.8 Protection against electrical HAZARDS from ME
       EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME
       EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
       HAZARDS
201.11 Protection against excessive temperatures and other
       HAZARDS
201.12 Accuracy of controls and instruments and protection
       against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMs
201.17 Electromagnetic compatibility of ME EQUIPMENT and
       ME SYSTEMS
202 Electromagnetic disturbances - Requirements and tests
208 General requirements, tests and guidance for alarm
       systems in medical electrical equipment and medical
       electrical systems
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - ELECTROMAGNETIC DISTURBANCES created
         by HF SURGICAL EQUIPMENT
Bibliography
Index of defined terms used i 3006 n this particular standard

BS EN 60601-2-2 Ed 6.0.

Committee
CH/62/4
DocumentType
Draft
Pages
81
PublisherName
British Standards Institution
Status
NA

IEC 60601-1-8:2006+AMD1:2012 CSV Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems
IEC 60601-2-18:2009 Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment
CENELEC GUIDE 29 : 2007 TEMPERATURES OF HOT SURFACES LIKELY TO BE TOUCHED GUIDANCE DOCUMENT FOR TECHNICAL COMMITTEES AND MANUFACTURERS
IEC 60601-2-4:2010 Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
AAMI HF18 : 2001 ERRATA 2001 ELECTROSURGICAL DEVICES
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.