• 97/541589 DC : DRAFT MAY 1997

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    PREN 12845 - FIXED FIREFIGHTING SYSTEMS - AUTOMATIC SPRINKLER SYSTEMS - DESIGN AND INSTALLATION

    Available format(s): 

    Superseded date:  26-08-2003

    Language(s): 

    Published date:  23-11-2012

    Publisher:  British Standards Institution

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Definitions
    4 Contract planning and documentation
       4.1 General
       4.2 Initial considerations
       4.3 Preliminary or estimating stage
       4.4 Design stage
    5 Extent of sprinkler protection
       5.1 Building and areas to be protected
       5.2 Storage in the open area
       5.3 Fire resisting compartments
       5.4 Protection of concealed spaces
    6 Classifications of occupancies and fire hazards
       6.1 General
       6.2 Hazard classes
       6.3 Storage
    7 Hydraulic design criteria
       7.1 LH, OH and HHP
       7.2 High hazards storage - HHS
       7.3 Pressure and flow requirements for precalculated systems
    8 Water supplies - General
       8.1 Suitability
       8.2 Connections for other services
       8.3 Housing of equipment for water supplies
       8.4 Test facility devices
       8.5 Pressure/flow tests on water supplies
       8.6 Water supplies pressure test
    9 Choice of water supply
       9.1 General
       9.2 Town mains
       9.3 Storage tanks
       9.4 Inexhaustible sources
       9.5 Pressure tanks
       9.6 Type of water supply
       9.7 Isolation of water supply
    10 Pumps
       10.1 General
       10.2 Multiple pump arrangements
       10.3 Compartments for pump sets
       10.4 Maximum temperature of water supply
       10.5 Valves and accessories
       10.6 Suction conditions
       10.7 Performance characteristics
       10.8 Electricity driven pump sets
       10.9 Diesel engine driven pump sets
    11 Installation type and size
       11.1 Wet pipe Installations
       11.2 Dry pipe Installations
       11.3 Alternate Installations
       11.4 Pre-actions Installations
       11.5 Subsidiary dry pipe or alternate extension
       11.6 Subsidiary water spray extension
    12 Spacing and location of sprinklers
       12.1 General
       12.2 Maximum area of coverage per sprinkler
       12.3 Maximum distance between sprinklers
       12.4 Location of sprinklers in relation to building
            construction
       12.5 Intermediate sprinklers in HH occupancies
    13 Pipe sizing and layout
       13.1 General
       13.2 Calculation of pressure losses in pipework
       13.3 Pre-calculated systems
       13.4 Fully calculated systems
    14 Sprinkler design characteristics and uses
       14.1 General
       14.2 Sprinkler types and application
       14.3 Flow from sprinklers
       14.4 Sprinkler temperature ratings
       14.5 Sprinkler thermal sensitivity
       14.6 Sprinkler guards
       14.7 Sprinkler water shields
       14.8 Sprinkler escutcheon plates
       14.9 Corrosion protection of sprinklers
    15 Valves
       15.1 Control valve sets
       15.2 Stop valves
       15.3 Ring main valves
       15.4 Drain valves
       15.5 Test valves
       15.6 Flushing connections
       15.7 Pressure gauges
    16 Alarms and alarm devices
       16.1 Water flow alarm
       16.2 Electrical water flow and pressure switches
    17 Pipework
       17.1 General
       17.2 Pipe supports
       17.3 Pipe work in concealed spaces
    18 Signs, notices and information
       18.1 Block plan
       18.2 Signs and notices
    19 Commissioning and acceptance tests
       19.1 Commissioning tests
       19.2 Completion certificate and documents
    20 Maintenance
       20.1 General
       20.2 Action following sprinkler operation
       20.3 User's programme of inspection and checking
       20.4 Services and maintenance schedule
    Annexes
    Annex A (normative) Classification of typical hazards
    Annex B (normative) Methodology for categorising stored goods
    Annex C (normative) Alphabetic listing of stored products and
                        categories
    Annex D (normative) Zoning of sprinkler installations
    Annex E (normative) Special requirements for high rise systems
    Annex F (normative) Special requirements for life safety systems
    Annex G (normative) Protection of special hazards
    Annex H (normative) Sprinkler systems monitoring
    Annex J (normative) Special technology

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee FSH/18/2
    Document Type Draft
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 274:1975 Copper tubes of circular section — Dimensions
    EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
    EN 12259-2:1999/A2:2005 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 2: WET ALARM VALVE ASSEMBLIES
    EN 12259-5:2002 Fixed firefighting systems - Components for sprinkler and water spray systems - Part 5: Water flow detectors
    ISO 3677:2016 Filler metal for soldering and brazing — Designation
    IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
    ISO 2016:1981 Capillary solder fittings for copper tubes Assembly dimensions and tests
    EN 65 : LATEST
    EN 12259-3:2000/A2:2005 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 3: DRY ALARM VALVE ASSEMBLIES
    EN 12259-1:1999 + A1:2001/A3:2006 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 1: SPRINKLERS
    EN 60095-1:1993/A12:1999 LEAD-ACID STARTER BATTERIES - PART 1: GENERAL REQUIREMENTS AND METHODS OF TEST
    IEC 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
    EN 12259-4:2000/A1:2001 Fixed firefighting systems - Components for sprinkler and water spray systems - Part 4: Water motor alarms
    EN ISO 9000:2015 Quality management systems - Fundamentals and vocabulary (ISO 9000:2015)
    EN 287-1:2011 Qualification test of welders - Fusion welding - Part 1: Steels
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective