AAMI IEC 60601-2-19 : 2009
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
MEDICAL ELECTRICAL EQUIPMENT - PART 2-19: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF INFANT INCUBATORS
Hardcopy , PDF
16-11-2018
23-07-2013
Glossary of equivalent standards
Committee representation
Background of AAMI adoption of IEC 60601-2-19:2009
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing ME
EQUIPMENT
201.6 Classification of ME EQUIPMENT and ME
SYSTEMS
201.7 ME EQUIPMENT identification, marking
and documents
201.8 Protection against electrical HAZARDS
from ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS
of ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
radiation HAZARDS
201.11 Protection against excessive temperatures
and other HAZARDS
201.12 Accuracy of controls and instruments and
protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT
and ME SYSTEMS
202 Electromagnetic compatibility - Requirements
and tests
210 Requirements for the development of physiologic
closed-loop controllers
Annexes
Annex AA (informative) - Particular guidance and rationale
Bibliography
Index of defined terms used in this particular standard
Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT INCUBATORS, as defined in 201.3.209 of this standard, also referred to as ME EQUIPMENT.
Committee |
II
|
DevelopmentNote |
Supersedes AAMI II36. (05/2009)
|
DocumentType |
Standard
|
Pages |
46
|
ProductNote |
NEW CHILD ERR 1 IS NOW ADDED.
NEW CHILD A1 IS NOW ADDED. |
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
IEC 60601-2-19:2009+AMD1:2016 CSV | Identical |
IEC 60601-2-21:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers |
IEC 60601-2-50:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-50: Particular requirementsfor the basic safety and essential performance of infant phototherapy equipment |
IEC 60601-1-10:2007+AMD1:2013 CSV | Medical electrical equipment - Part 1-10: General requirements forbasic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loopcontrollers |
IEC 60601-2-20:2009+AMD1:2016 CSV | Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transportincubators |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.