AAMI TIR34 : 2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
WATER FOR THE REPROCESSING OF MEDICAL DEVICES
Hardcopy , PDF
25-01-2020
English
01-01-2014
Glossary of equivalent standards
Committee representation
Foreword
Introduction
1 Scope
2 Definitions and abbreviations
3 The importance of water quality
and effective water treatment
4 Categories of water quality for
medical device reprocessing
5 Selection of water quality
6 Water treatment systems
7 Monitoring water quality
8 Strategies for bacterial control
9 Personnel considerations
10 Continuous quality improvement
Annexes
Annex A (informative) - Water treatment methods
Annex B (informative) - Monitoring water treatment equipment
and processes
Annex C (informative) - Water storage and distribution
Annex D (informative) - Strategies for bacterial control
Annex E (informative) - Thermal disinfection
Annex F (informative) - water treatment using filtration
Annex G (informative) - Typical presentation of water quality
issues during the reprocessing of medical devices
Annex H - Bibliography
Describes the water quality needs for reprocessing various categories of medical devices at various stages of reprocessing and how to assess, generate, monitor, and maintain water meeting those requirements.
DocumentType |
Standard
|
Pages |
642
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
CSA Z314.3 : 2009 : R2014 | EFFECTIVE STERILIZATION IN HEALTH CARE SETTINGS BY THE STEAM PROCESS |
CSA Z314.8 : 2014 | DECONTAMINATION OF REUSABLE MEDICAL DEVICES |
ANSI/AAMI ST8:2013(R2018) | HOSPITAL STEAM STERILIZERS |
AAMI TIR58 : 2014 | WATER TESTING METHODOLOGIES |
AAMI TIR30 : 2011 | A COMPENDIUM OF PROCESSES, MATERIALS, TEST METHODS, AND ACCEPTANCE CRITERIA FOR CLEANING REUSABLE MEDICAL DEVICES |
AAMI TIR 12 : 2010 | DESIGNING, TESTING, AND LABELING REUSABLE MEDICAL DEVICES FOR REPROCESSING IN HEALTH CARE FACILITIES: A GUIDE FOR MEDICAL DEVICE MANUFACTURERS |
ANSI/AAMI ST79:2017 | COMPREHENSIVE GUIDE TO STEAM STERILIZATION AND STERILITY ASSURANCE IN HEALTH CARE FACILITIES |
CSA Z317.1 : 2016 | SPECIAL REQUIREMENTS FOR PLUMBING INSTALLATIONS IN HEALTH CARE FACILITIES |
CSA Z314.3 : 2009 | EFFECTIVE STERILIZATION IN HEALTH CARE SETTINGS BY THE STEAM PROCESS |
CAN/CSA-Z314-18 | Canadian medical device reprocessing |
AAMI TIR30:2011(R2016) | A COMPENDIUM OF PROCESSES, MATERIALS, TEST METHODS, AND ACCEPTANCE CRITERIA FOR CLEANING REUSABLE MEDICAL DEVICES |
AAMI ST91 : 2015 | FLEXIBLE AND SEMI-RIGID ENDOSCOPE PROCESSING IN HEALTH CARE FACILITIES |
AAMI TIR16 : 2017 | MICROBIOLOGICAL ASPECTS OF ETHYLENE OXIDE STERILIZATION |
ANSI/AAMI ST58:2013(R2018) | CHEMICAL STERILIZATION AND HIGH-LEVEL DISINFECTION IN HEALTH CARE FACILITIES |
ANSI/AAMI ST55:2016 | TABLE-TOP STEAM STERILIZERS |
CSA Z314.0 : 2013 | MEDICAL DEVICE REPROCESSING - GENERAL REQUIREMENTS |
CSA Z317.2 : 2010 | SPECIAL REQUIREMENTS FOR HEATING, VENTILATION, AND AIR-CONDITIONING (HVAC) SYSTEMS IN HEALTH CARE FACILITIES |
ISO 15883-1:2006 | Washer-disinfectors Part 1: General requirements, terms and definitions and tests |
CSA Z314.8 : 2014 | DECONTAMINATION OF REUSABLE MEDICAL DEVICES |
ASTM F 1518 : 2000 | Standard Practice for Cleaning and Disinfection of Flexible Fiberoptic and Video Endoscopes Used in the Examination of the Hollow Viscera (Withdrawn 2009) |
ISO 15883-3:2006 | Washer-disinfectors — Part 3: Requirements and tests for washer-disinfectors employing thermal disinfection for human waste containers |
AAMI ISO 26722 : 2009 | WATER TREATMENT EQUIPMENT FOR HEMODIALYSIS APPLICATIONS AND RELATED THERAPIES |
AAMI ST15883-3 : 2012 | WASHER-DISINFECTORS - PART 3: REQUIREMENTS AND TESTS FOR WASHER-DISINFECTORS EMPLOYING THERMAL DISINFECTION FOR HUMAN WASTE CONTAINERS |
ANSI/AAMI ST55:2016 | TABLE-TOP STEAM STERILIZERS |
ISO/TS 15883-5:2005 | Washer-disinfectors Part 5: Test soils and methods for demonstrating cleaning efficacy |
AAMI ISO 11663 : 2009 | QUALITY OF DIALYSIS FLUID FOR HAEMODIALYSIS AND RELATED THERAPIES |
ISO 15883-4:2008 | Washer-disinfectors Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes |
AAMI RD47 : 2008 | REPROCESSING OF HEMODIALYZERS |
AAMI ISO 13959 : 2009 | WATER FOR HEMODIALYSIS AND RELATED THERAPIES |
ANSI/AAMI ST79:2017 | COMPREHENSIVE GUIDE TO STEAM STERILIZATION AND STERILITY ASSURANCE IN HEALTH CARE FACILITIES |
AAMI ST15883-2 : 2013 | WASHER-DISINFECTORS - PART 2: REQUIREMENTS AND TESTS FOR WASHER-DISINFECTORS EMPLOYING THERMAL DISINFECTION FOR SURGICAL INSTRUMENTS, ANESTHETIC EQUIPMENT, BOWLS, DISHES, RECEIVERS, UTENSILS, GLASSWARE, ETC. |
ISO 15883-2:2006 | Washer-disinfectors — Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for surgical instruments, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc. |
AAMI ST15883-1 : 2009 | WASHER-DISINFECTORS - PART 1: GENERAL REQUIREMENTS, TERMS AND DEFINITIONS AND TESTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.