• There are no items in your cart

ACI 506.2 : 2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

SPECIFICATION FOR SHOTCRETE

Available format(s)

Hardcopy , PDF

Superseded date

28-11-2019

Superseded by

ACI 506.2 : 2013(R2018)

Language(s)

English

Published date

01-01-2013

€52.94
Excluding VAT

PART 1—GENERAL 1.1—Scope 1.2—Definitions 1.3—Referenced standards 1.4—Submittals 1.5—Preconstruction testing by Contractor 1.6—Testing during construction 1.7—Delivery, storage, and handling PART 2—PRODUCTS 2.1—Materials 2.2—Packaged shotcrete materials 2.3—Fiber-reinforced shotcrete 2.4—Shotcrete properties 2.5—Proportioning 2.6—Batching, mixing, and delivery PART 3—EXECUTION 3.1—Preparation of surface to receive shotcrete 3.2—Joints 3.3—Alignment control 3.4—Application 3.5—Finish 3.6—Curing 3.7—Protection 3.8—Tolerances 3.9—Repair of shotcrete 3.10—Acceptance of Wor (nonmandatory portion follows) NOTES TO SPECIFIER General notes

Includes the construction requirements for the application of shotcrete. Both wet-mix and dry-mix shotcrete are specified, and the minimum standards for testing, materials, and execution are provided.

Committee
506
DocumentType
Revision
Pages
16
PublisherName
American Concrete Institute
Status
Superseded
SupersededBy
Supersedes

ACI ITG-9R : 2016 REPORT ON DESIGN OF CONCRETE WIND TURBINE TOWERS
ACI 376 : 2011 CODE REQUIREMENTS FOR DESIGN AND CONSTRUCTION OF CONCRETE STRUCTURES FOR THE CONTAINMENT OF REFRIGERATED LIQUEFIED GASES AND COMMENTARY
ANSI/AWWA D110:2013(R2018) WIRE- AND STRAND-WOUND, CIRCULAR, PRESTRESSED CONCRETE WATER TANKS
ASTM C 1116/C1116M : 2010 : REV A : R2015 Standard Specification for Fiber-Reinforced Concrete
NFPA 5000 : 2018 BUILDING CONSTRUCTION AND SAFETY CODE
CSA S448.1 : 2010 : R2015 REPAIR OF REINFORCED CONCRETE IN BUILDINGS AND PARKING STRUCTURES
ACI 544.4R : 1988 DESIGN CONSIDERATIONS FOR STEEL FIBER REINFORCED CONCRETE
CSA S448.1 : 2010 REPAIR OF REINFORCED CONCRETE IN BUILDINGS AND PARKING STRUCTURES
CTI ESG 123 : 2012 RECOMMENDED GUIDELINES FOR CONCRETE RESTORATION AND REPAIRS TO NATURAL AND MECHANICAL DRAFT COOLING TOWERS
ASTM C 1116/C1116M : 2010 Standard Specification for Fiber-Reinforced Concrete
ACI 506.1R : 2008 GUIDE TO FIBER-REINFORCED SHOTCRETE
ASTM C 1604/C1604M : 2005 Standard Test Method for Obtaining and Testing Drilled Cores of Shotcrete
ASTM C 1604/C1604M : 2005 : R2012 Standard Test Method for Obtaining and Testing Drilled Cores of Shotcrete
ACI 544.1R : 1996 REPORT ON FIBER REINFORCED CONCRETE
ACI PRC-506 : 2016 GUIDE TO SHOTCRETE
ACI 350.5 : 2012 SPECIFICATIONS FOR ENVIRONMENTAL CONCRETE STRUCTURES
ACI 506.3R : 1991 GUIDE TO CERTIFICATION OF SHOTCRETE NOZZLEMEN
ACI 210R : 1993 EROSION OF CONCRETE IN HYDRAULIC STRUCTURES
ACI 506.4R : 1994 GUIDE FOR THE EVALUATION OF SHOTCRETE
ASTM C 1116/C1116M : 2010 : REV A Standard Specification for Fiber-Reinforced Concrete
ACI 376M : 2011 CODE REQUIREMENTS FOR DESIGN AND CONSTRUCTION OF CONCRETE STRUCTURES FOR THE CONTAINMENT OF REFRIGERATED LIQUEFIED GASES (METRIC)
ACI 308 : 92(R1997) PRACTICE FOR CURING CONCRETE
ACI 334.3R : 2005 CONSTRUCTION OF CONCRETE SHELLS USING INFLATED FORMS
ACI PRC-308 : 2016 GUIDE TO EXTERNAL CURING OF CONCRETE
ASTM C 1480 : 2000 Standard Specification for Packaged, Pre-Blended, Dry, Combined Materials for Use in Wet or Dry Shotcrete Application
ASTM C 1480 : 2000 : R2005 Standard Specification for Packaged, Pre-Blended, Dry, Combined Materials for Use in Wet or Dry Shotcrete Application

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.