Section 1. Purpose
Section 2. Scope
Section 3. Definitions
Section 4. Classifications
Section 5. Test Requirements
Section 6. Rating Requirements
Section 7. Minimum Data Requirements for Published Ratings
Section 8. Operating Requirements
Section 9. Marking and Nameplate Data
Section 10. Conformance Conditions
APPENDICES
Appendix A. References - Normative
Appendix B. References - Informative
Appendix C. Condenser Entering Air Temperature
Measurement - Normative
Appendix D. Atmospheric Pressure Correction - Normative
Appendix E. Unit Configuration for Standard Efficiency
Determination - Informative
Appendix F. Method of Testing Unitary Air Conditioning
Products - Normative
Appendix G. Examples of IEER Calculations - Informative
Pertains to factory-made Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment as defined in Section 3.
DevelopmentNote |
Supersedes AHRI 340/360. Effective date 01/01/2017. (05/2016)
|
DocumentType |
Standard
|
PublisherName |
Air-Conditioning, Heating and Refrigeration Institute
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
ASHRAE 41.1 : 2013 | STANDARD METHOD FOR TEMPERATURE MEASUREMENT |
AHRI 110 : 2002 | AIR-CONDITIONING, HEATING AND REFRIGERATING EQUIPMENT NAMEPLATE VOLTAGES |
ASHRAE 37 : 2009 | METHODS OF TESTING FOR RATING ELECTRICALLY DRIVEN UNITARY AIR-CONDITIONING AND HEAT PUMP EQUIPMENT |
AHRI 390 : 2003 | PERFORMANCE RATING OF SINGLE PACKAGE VERTICAL AIR-CONDITIONERS AND HEAT PUMPS |
AHRI 520 : 2004 | PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS |
AHRI 365 (I-P) : 2009 | PERFORMANCE RATING OF COMMERCIAL AND INDUSTRIAL UNITARY AIR-CONDITIONING CONDENSING UNITS |
AHRI 470 : 2001 | PERFORMANCE RATING OF DESUPERHEATER/WATER HEATERS |
ISO 5151:2017 | Non-ducted air conditioners and heat pumps — Testing and rating for performance |
ASTM G 85 : 2011 : REDLINE | Standard Practice for Modified Salt Spray (Fog) Testing |
ASHRAE 90.1 : 1999 | ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS |
AHRI 210/240 : 2006 | PERFORMANCE RATING OF UNITARY AIR-CONDITIONING AND AIR-SOURCE HEAT PUMP EQUIPMENT |
ASHRAE 62.1 : 2016 | VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY |
CFR 10(PTS400-499) : JAN 96 | ENERGY |
AHRI 540 : 2004 | PERFORMANCE RATING OF POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS AND COMPRESSOR UNITS |
ISO 13253:2017 | Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance |
ASHRAE 34 : 2013 | DESIGNATION AND SAFETY CLASSIFICATION OF REFRIGERANTS |
ISO 13256-1:1998 | Water-source heat pumps Testing and rating for performance Part 1: Water-to-air and brine-to-air heat pumps |
AHRI 920 (I-P) : 2015 | PERFORMANCE RATING OF DX-DEDICATED OUTDOOR AIR SYSTEM UNITS |
C22.2 NO. 236-15 | Heating and cooling equipment (Bi-national standard with UL 1995) |
ISO 15042:2017 | Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance |
AHRI GUIDELINE V (I-P) : 2011 | CALCULATING THE EFFICIENCY OF ENERGY RECOVERY VENTILATION AND ITS EFFECT ON EFFICIENCY AND SIZING OF BUILDING HVAC SYSTEMS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.