ANSI/AAMI/ISO 15674:2016
Current
The latest, up-to-date edition.
CARDIOVASCULAR IMPLANTS AND ARTIFICIAL ORGANS - HARD-SHELL CARDIOTOMY/VENOUS RESERVOIR SYSTEMS (WITH/WITHOUT FILTER) AND SOFT VENOUS RESERVOIR BAGS
Hardcopy , PDF
English
28-11-2016
Glossary of equivalent standards
Committee representation
Background of AAMI adoption of ISO 15674:2016
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Tests and measurements to determine
compliance with this document
6 Information supplied by the manufacturer
7 Packaging
Annex A (normative) - Factors to be considered
in evaluating performance characteristics
Bibliography
Describes requirements for sterile, single-use, extracorporeal hard-shell cardiotomy/venous reservoir systems and soft venous reservoir bags intended for use as a blood reservoir during cardiopulmonary bypass (CPB) surgery.
| DocumentType |
Standard
|
| ISBN |
978-1-57020-636-8
|
| Pages |
21
|
| PublisherName |
Association for the Advancement of Medical Instrumentation
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| ISO 15674:2016 | Identical |
| ISO 11137-1:2006 | Sterilization of health care products — Radiation — Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
| ISO 11607-2:2006 | Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes |
| ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
| ISO 8637:2010 | Cardiovascular implants and extracorporeal systems — Haemodialysers, haemodiafilters, haemofilters and haemoconcentrators |
| ISO 13485:2016 | Medical devices — Quality management systems — Requirements for regulatory purposes |
| ISO 14937:2009 | Sterilization of health care products — General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
| ISO/TS 23810:2012 | Cardiovascular implants and artificial organs — Checklist for preoperative extracorporeal circulation equipment setup |
| ISO 7199:2016 | Cardiovascular implants and artificial organs — Blood-gas exchangers (oxygenators) |
| ISO 10993-11:2017 | Biological evaluation of medical devices — Part 11: Tests for systemic toxicity |
| ISO 10993-7:2008 | Biological evaluation of medical devices — Part 7: Ethylene oxide sterilization residuals |
| ISO 10993-1:2009 | Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process |
| ISO 14971:2007 | Medical devices — Application of risk management to medical devices |
| ISO 11607-1:2006 | Packaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier systems and packaging systems |
| ISO 594-2:1998 | Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment — Part 2: Lock fittings |
| ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.