ANSI/AAMI/ISO 25539-2:2012
Current
The latest, up-to-date edition.
CARDIOVASCULAR IMPLANTS - ENDOVASCULAR DEVICES - PART 2: VASCULAR STENTS
Hardcopy , PDF
English
04-12-2012
Glossary of equivalent standards
Committee representation
Background of ANSI/AAMI adoption of ISO 25539-2:2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Intended performance
6 Design attributes
7 Materials
8 Design evaluation
9 Post-market surveillance
10 Manufacturing
11 Sterilization
12 Packaging
Annex A (informative) - Attributes of endovascular
devices - Vascular stents - Technical and
clinical consideration
Annex B (informative) - Bench and analytical tests
Annex C (informative) - Definitions of reportable
clinical events
Annex D (informative) - Test methods
Annex E (informative) - Supplement to fatigue durability
test analytical approach
Bibliography
Describes requirements for vascular stents, based upon current medical knowledge.
Committee |
WG 03
|
DocumentType |
Standard
|
ISBN |
1-57020-480-2
|
Pages |
116
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
ISO 25539-2:2012 | Identical |
ISO 11070:2014 | Sterile single-use intravascular introducers, dilators and guidewires |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
ISO 14160:2011 | Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices |
ISO 10555-2:1996 | Sterile, single-use intravascular catheters Part 2: Angiographic catheters |
ISO 7198:2016 | Cardiovascular implants and extracorporeal systems — Vascular prostheses — Tubular vascular grafts and vascular patches |
ASTM F 2503 : 2013 : REDLINE | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ISO 17475:2005 | Corrosion of metals and alloys — Electrochemical test methods — Guidelines for conducting potentiostatic and potentiodynamic polarization measurements |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
ISO/TR 14969:2004 | Medical devices Quality management systems Guidance on the application of ISO 13485: 2003 |
ISO 11135-1:2007 | Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 14630:2012 | Non-active surgical implants — General requirements |
ASTM F 2052 : 2015 : REDLINE | Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment |
ISO/TS 15539:2000 | Cardiovascular implants Endovascular prostheses |
ASTM F 2213 : 2017 : REDLINE | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
EN 12006-3:1998+A1:2009 | Non active surgical implants - Particular requirements for cardiac and vascular implants - Part 3: Endovascular devices |
ISO 10555-3:2013 | Intravascular catheters — Sterile and single-use catheters — Part 3: Central venous catheters |
ISO 10555-1:2013 | Intravascular catheters — Sterile and single-use catheters — Part 1: General requirements |
EN 14299:2004 | Non active surgical implants - Particular requirements for cardiac and vascular implants - Specific requirements for arterial stents |
ISO 14155:2011 | Clinical investigation of medical devices for human subjects Good clinical practice |
ISO 11134:1994 | Sterilization of health care products — Requirements for validation and routine control — Industrial moist heat sterilization |
ISO/TS 11135-2:2008 | Sterilization of health care products Ethylene oxide Part 2: Guidance on the application of ISO 11135-1 |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
ASTM D 638 : 2014 : REDLINE | Standard Test Method for Tensile Properties of Plastics |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
ISO 10555-4:2013 | Intravascular catheters — Sterile and single-use catheters — Part 4: Balloon dilatation catheters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.