    Foreword
    1 Scope
    2 Referenced and Related Standards
      2.1 Referenced American National Standards
      2.2 Related American National Standards
    3 General Test Conditions
    4 Conformance Test Requirements
      4.1 General
      4.2 Test requirements
      4.3 Test arrangement
          4.3.1 Switchgear vertical section
          4.3.2 Test enclosure
          4.3.3 Grounding of test enclosures or switchgear
                 vertical section
      4.4 Commonalities of design and test
      4.5 Lightning impulse withstand test
          4.5.1 General
          4.5.2 Description of test
          4.5.3 Procedures
          4.5.4 Number of tests
          4.5.5 Performance
      4.6 Continuous current test
          4.6.1 Test arrangement
          4.6.2 Continuous current test
          4.6.3 Test area conditions
          4.6.4 Ambient air temperature limits
          4.6.5 Measurement of ambient air temperature
          4.6.6 Measurement of equipment temperature
          4.6.7 Duration of tests
          4.6.8 Frequency of test current
          4.6.9 Copper conductors for use in continuous current
                 tests
          4.6.10 Performance
      4.7 Short-circuit tests
          4.7.1 Test arrangements
          4.7.2 Momentary withstand current test
          4.7.3 Short-time withstand current test
      4.8 Mechanical endurance test
          4.8.1 Test arrangement
          4.8.2 Power operation
          4.8.3 Manual operation
          4.8.4 Mechanical endurance test requirements
          4.8.5 Performance
      4.9 Load-switching current test (if rated)
          4.9.1 Test arrangement
          4.9.2 Grounding
          4.9.3 Test voltage and current
          4.9.4 Load-switching current test circuit
          4.9.5 Performance
    5 Treatment of Failures
    6 Product Retest Requirements
    Tables
    Figures

    Abstract - (Show below) - (Hide below)

    Applies to the conformance test procedure for AC medium-voltage switches rated 1000 volts as designed, manufactured, and tested in accordance with ANSI/IEEE C37.20.4.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher National Electrical Manufacturers Association
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE C37.59-2007 IEEE Standard Requirements for Conversion of Power Switchgear Equipment
    ANSI C37.57 : 1990 SWITCHGEAR - METAL-ENCLOSED INTERRUPTER SWITCHGEAR ASSEMBLIES - CONFORMANCE TESTING
    ANSI C37.55 : 1989 MEDIUM VOLTAGE METAL-CLAD ASSEMBLIES - CONFORMANCE TEST PROCEDURES
    NEMA SG 5-1995 POWER SWITCHGEAR ASSEMBLIES
    UL 1008A:2ED 2017-09 Transfer Switch Equipment, Over 1000 Volts
    CSA C22.2 NO. 178.3:17 Transfer switch equipment, over 1000 volts (Binational standard with UL 1008A)
    IEEE 1247 : 2005 INTERRUPTER SWITCHES FOR ALTERNATING CURRENT, RATED ABOVE 1000 V
    IEEE C37.20.4-2013 REDLINE IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed Switchgear

    Standards Referencing This Book - (Show below) - (Hide below)

    ANSI C37.57 : 1990 SWITCHGEAR - METAL-ENCLOSED INTERRUPTER SWITCHGEAR ASSEMBLIES - CONFORMANCE TESTING
    IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
    IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
    ANSI C37.55 : 1989 MEDIUM VOLTAGE METAL-CLAD ASSEMBLIES - CONFORMANCE TEST PROCEDURES
    IEEE C37.20.3-2013 REDLINE IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV)
    IEEE C37.20.4-2013 REDLINE IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed Switchgear
    IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
    ANSI C37.22:1997 AMERICAN NATIONAL STANDARD PREFERRED RATINGS AND RELATED REQUIRED CAPABLITIES FOR INDOOR AC MEDIUM VOLTAGE SWITCHES USED IN METAL-ENCLOSED SWITCHGEAR
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective