• ANSI INCITS 336 : 2000

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    INFORMATION TECHNOLOGY - SCSI PARALLEL INTERFACE-3 (SPI-3)

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  23-07-2013

    Language(s):  English

    Published date:  01-01-2000

    Publisher:  Information Technology Industry Council

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
       2.1 Normative references
       2.2 Approved references
       2.3 References under development
       2.4 Other references
    3 Definitions, symbols, abbreviations, and conventions
       3.1 Definitions
       3.2 Symbols and abbreviations
       3.3 Keywords
       3.4 Conventions
       3.5 Notation for Procedures and Functions
    4 General
       4.1 General overview
       4.2 Cables, Connectors, Signals, Transceivers
       4.3 Physical architecture of bus
       4.4 Physical topology details and definitions
       4.5 Bus loading
       4.6 Termination requirements
       4.7 SCSI device Addressing
       4.8 Data transfers
       4.9 Data transfer modes
       4.10 Protocol
    5 SCSI parallel interface connectors
       5.1 SCSI parallel interface connectors overview
       5.2 Nonshielded connector
       5.3 Shielded connector
       5.4 Connector contact assignments
    6 SCSI bus interconnect
       6.1 SCSI bus interconnect overview
       6.2 SCSI bus cables
       6.3 Interconnect characteristics for signals
       6.4 Decoupling characteristics for TERMPWR lines
       6.5 Connection requirements for RESERVED lines
       6.6 Cables used with SE transceivers
       6.7 SE ground offset
       6.8 Cables used with LVD transceivers
       6.9 LVD stub length and spacing
    7 SCSI parallel interface electrical characteristics
       7.1 SCSI parallel interface electrical characteristics overview
       7.2 SE alternative
       7.3 LVD alternative
       7.4 LVD/MSE multimode alternative
       7.5 Terminator power
    8 SCSI bus signals
       8.1 SCSI bus signals overview
       8.2 Signal descriptions
       8.3 Signal states
       8.4 OR-tied signals
       8.5 Signal sources
    9 SCSI parallel bus timing
       9.1 SCSI parallel bus timing values
       9.2 Timing description
       9.3 Measurement points
       9.4 Setup and hold timings
    10 SCSI bus phases
       10.1 SCSI bus phases overview
       10.2 BUS FREE phase
       10.3 Unexpected bus free phases
       10.4 Expected bus free phases
       10.5 Arbitration
       10.6 SELECTION phase
       10.7 RESELECTION phase
       10.8 Information transfer phases
       10.9 COMMAND phase
       10.10 DATA phase
       10.11 STATUS phase
       10.12 MESSAGE phase
       10.13 Signal restrictions between phases
    11 DATA BUS protection
       11.1 DATA BUS protection overview
       11.2 ST DATA BUS protection (parity)
       11.3 DT DATA BUS protection (CRC)
    12 SCSI bus conditions
       12.1 SCSI bus conditions overview
       12.2 Attention condition
       12.3 Hard reset
       12.4 Reset events
    13 SCSI bus phase sequences
       13.1 SCSI bus phase sequences overview
       13.2 Phase sequences for physical reconnection and selection
            using attention condition with information unit transfers
            disabled
       13.3 Phase sequences for selection without using attention
            condition with information unit transfers disabled
       13.4 Phase sequences for selection without using attention
            condition/physical reconnection with information unit
            transfers enabled
       13.5 Phase sequences for physical selection using attention
            condition with information unit transfers enabled
    14 SPI information unit sequences
       14.1 SPI information unit overview
       14.2 Information unit transfer logical operations
       14.3 SPI information units
    15 SCSI pointers
    16 SCSI messages
       16.1 SCSI messages overview
       16.2 Message protocols and formats
       16.3 Link control messages
       16.4 Task attribute messages
       16.5 Task management messages
    17 Command processing considerations and exception conditions
       17.1 Command processing considerations and exception conditions
            overview
       17.2 Asynchronous event notification
       17.3 Incorrect initiator connection
       17.4 Unexpected RESELECTION phase
    18 SCSI management features for the SCSI parallel interface
       18.1 SCSI mode parameters
    19 SCSI parallel interface services
       19.1 SCSI parallel interface services overview
       19.2 Procedure objects
       19.3 Application client SCSI command services
       19.4 Device server SCSI command services
       19.5 Task management services
    Annexes
    A Additional requirements for LVD SCSI drivers and receivers
    B SCSI bus fairness
    C Nonshielded connector alternative 4
    D Removal and insertion of SCSI devices
    E SCSI cable media performance testing
    F Interconnecting buses of different widths
    G Transmission line considerations for SE fast-20 data transfer
       rates
    H Measuring SE pin capacitance
    I SCSI ICONS
    J Backplane construction guidelines
    K SPI-3 to SCSI-2 terminology mapping
    L Physical layer integrity checking
    M Alternate error detection for the asynchronous information
       phases (COMMAND, MESSAGE, and STATUS)

    Abstract - (Show below) - (Hide below)

    Delineates the mechanical, electrical, timing, and protocol requirements of the SCSI parallel interface to allow conforming SCSI devices to inter-operate. The SCSI parallel interface is a local I/O bus that may be operated over a wide range of transfer rates.

    General Product Information - (Show below) - (Hide below)

    Committee X3T10
    Document Type Standard
    Publisher Information Technology Industry Council
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    ANSI INCITS 369 : 2003 : R2008 INFORMATION TECHNOLOGY - SCSI SIGNAL MODELING-2 (SSM-2)
    CSA ISO/IEC 14776-412 : 2007 : R2012 INFORMATION TECHNOLOGY - SMALL COMPUTER SYSTEM INTERFACE (SCSI) - PART 412: ARCHITECTURE MODEL-2 (SAM-2)
    ISO/IEC 14776-413:2007 Information technology Small Computer System Interface (SCSI) Part 413: SCSI Architecture Model -3 (SAM-3)
    ANSI INCITS 369 : 2003(R2018) INFORMATION TECHNOLOGY - SCSI SIGNAL MODELING-2 (SSM-2)
    ANSI INCITS TR 29 : 2002 INFORMATION TECHNOLOGY - SCSI SIGNAL MODELING (SSM)
    ANSI INCITS 360 : 2002 INFORMATION TECHNOLOGY - SCSI MULTIMEDIA COMMANDS - 3 (MMC-3)
    ANSI INCITS 401 : 2005 : R2015 INFORMATION TECHNOLOGY - SCSI MULTIMEDIA COMMANDS - 4 (MMC-4)
    ANSI INCITS 360 : 2002 : R2007 INFORMATION TECHNOLOGY - SCSI MULTIMEDIA COMMANDS - 3 (MMC-3)
    CSA ISO/IEC 14776-413 : 2007 : R2012 INFORMATION TECHNOLOGY - SMALL COMPUTER SYSTEM INTERFACE (SCSI) - PART 413: ARCHITECTURE MODEL-3 (SAM-3)
    CAN/CSA-ISO/IEC 14776-412-07 (R2017) Information Technology - Small Computer System Interface (SCSI) - Part 412: Architecture Model-2 (SAM-2) (Adopted ISO/IEC 14776-412:2006, first edition, 2006-10)
    ANSI INCITS 401 : 2005 INFORMATION TECHNOLOGY - SCSI MULTIMEDIA COMMANDS - 4 (MMC-4)
    CSA ISO/IEC 14776-412:2007 INFORMATION TECHNOLOGY - SMALL COMPUTER SYSTEM INTERFACE (SCSI) - PART 412: ARCHITECTURE MODEL-2 (SAM-2)
    CAN/CSA-ISO/IEC 14776-413-07 (R2017) Information Technology - Small Computer System Interface (SCSI) - Part 413: Architecture Model-3 (SAM-3) (Adopted ISO/IEC 14776-413:2007, first edition, 2007-02)
    CSA ISO/IEC 14776-413 : 2007 INFORMATION TECHNOLOGY - SMALL COMPUTER SYSTEM INTERFACE (SCSI) - PART 413: ARCHITECTURE MODEL-3 (SAM-3)
    ISO/IEC 14776-322:2007 Information technology Small Computer System Interface (SCSI) Part 322: SCSI Block Commands - 2 (SBC-2)

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM D 4566 : 2014 : REDLINE Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable
    IEEE 1364-2005 IEEE Standard for Verilog Hardware Description Language
    IEC 60512-11-7:2003 Connectors for electronic equipment - Tests and measurements - Part 11-7: Climatic tests - Test 11g: Flowing mixed gas corrosion test
    ISO/IEC 8482:1993 Information technology Telecommunications and information exchange between systems Twisted pair multipoint interconnections
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective