• There are no items in your cart

ANSI N42.3 : 1999(R2006)

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

IEEE STANDARD TEST PROCEDURES AND BASES FOR GEIGER-MUELLER COUNTERS

Withdrawn date

16-03-2022

Published date

12-01-2013

Sorry this product is not available in your region.

1. Overview
1.1 Scope
1.2 Purpose
2. References
3. Definitions, symbols, abbreviations, and acronyms
3.1 Definitions
3.2 Symbols, abbreviations, and acronyms
4. General
5. Test conditions
5.1 Radiation Background
5.2 Ambient Temperature
5.3 Radiation Sources
5.4 Photon sources
5.5 Alpha- and beta-ray sources
5.6 Geiger-Mueller counter test circuits
6. Geiger-Muller counter parameters
6.1 Background counting rate
6.2 Response to ionizing radiation
6.3 Geiger-Muller threshold
6.4 Plateau characteristics
6.5 Life
6.6 Radial sensitivity of end-window counter
6.7 Longitudinal sensitivity of cylindrical counter
6.8 Temperature dependence
6.9 Hysteresis
6.10 Photosensitivity
7. Measurement of Geiger-Muller characteristics
7.1 Current mode
7.2 Pulse-shape
8. Test Equipment
8.1 Voltmeter
8.2 Ammeter
8.3 Oscilloscope
8.4 Counting System
8.5 Count-Rate Meter
8.6 High-Voltage Supply
8.7 Capacitance Bridge
8.8 Single-channel analyzer
9. Specifications of Geiger-Mueller counters
9.1 Geiger-Mueller counter construction
9.2 Standard connections
9.3 Anode resistors
Annex A (informative) Bibliography

Applicable to Geiger-Mueller (G-M) counters for use in the detection and counting of individual particles.

Committee
ANSI
DevelopmentNote
This is a dual numbered document with IEEE 309. (06/1999)
DocumentType
Standard
PublisherName
American National Standards Institute
Status
Withdrawn

IEEE/ANSI N42.32-2006 American National Standard Performance Criteria for Alarming Personal Radiation Detectors for Homeland Security

IEEE N42.12-1994 American National Standard Calibration and Usage of Thallium-Activated Sodium Iodide Detector Systems for Assay of Radionuclides
IEC 60151-25:1971 Measurements of the electrical properties of electronic tubes - Part 25: Methods of measurement of Geiger-Müller counter tubes
ISO 4037-2:1997 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
ISO 4037-1:1996 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods
ISO 7503-1:2016 Measurement of radioactivity Measurement and evaluation of surface contamination Part 1: General principles

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.