ANSI N42.3 : 1999(R2006)
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
IEEE STANDARD TEST PROCEDURES AND BASES FOR GEIGER-MUELLER COUNTERS
16-03-2022
12-01-2013
1. Overview
1.1 Scope
1.2 Purpose
2. References
3. Definitions, symbols, abbreviations, and acronyms
3.1 Definitions
3.2 Symbols, abbreviations, and acronyms
4. General
5. Test conditions
5.1 Radiation Background
5.2 Ambient Temperature
5.3 Radiation Sources
5.4 Photon sources
5.5 Alpha- and beta-ray sources
5.6 Geiger-Mueller counter test circuits
6. Geiger-Muller counter parameters
6.1 Background counting rate
6.2 Response to ionizing radiation
6.3 Geiger-Muller threshold
6.4 Plateau characteristics
6.5 Life
6.6 Radial sensitivity of end-window counter
6.7 Longitudinal sensitivity of cylindrical counter
6.8 Temperature dependence
6.9 Hysteresis
6.10 Photosensitivity
7. Measurement of Geiger-Muller characteristics
7.1 Current mode
7.2 Pulse-shape
8. Test Equipment
8.1 Voltmeter
8.2 Ammeter
8.3 Oscilloscope
8.4 Counting System
8.5 Count-Rate Meter
8.6 High-Voltage Supply
8.7 Capacitance Bridge
8.8 Single-channel analyzer
9. Specifications of Geiger-Mueller counters
9.1 Geiger-Mueller counter construction
9.2 Standard connections
9.3 Anode resistors
Annex A (informative) Bibliography
Applicable to Geiger-Mueller (G-M) counters for use in the detection and counting of individual particles.
Committee |
ANSI
|
DevelopmentNote |
This is a dual numbered document with IEEE 309. (06/1999)
|
DocumentType |
Standard
|
PublisherName |
American National Standards Institute
|
Status |
Withdrawn
|
IEEE/ANSI N42.32-2006 | American National Standard Performance Criteria for Alarming Personal Radiation Detectors for Homeland Security |
IEEE N42.12-1994 | American National Standard Calibration and Usage of Thallium-Activated Sodium Iodide Detector Systems for Assay of Radionuclides |
IEC 60151-25:1971 | Measurements of the electrical properties of electronic tubes - Part 25: Methods of measurement of Geiger-Müller counter tubes |
ISO 4037-2:1997 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
ISO 7503-1:2016 | Measurement of radioactivity Measurement and evaluation of surface contamination Part 1: General principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.