• ANSI Z21.11.3-2016

    Current The latest, up-to-date edition.

    Gas-fired room heaters, volume III, propane-fired portable emergency use heater systems

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2016

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Preface
    1 Scope
    2 Reference publications
    3 Definitions
    4 Construction
    5 Performance
    6 Manufacturing and production tests
    Annex A (normative) - Sample failure modes and effects
            analysis for component miswiring
    Annex B (normative) - Glass temperature calculation
    Annex C (normative) - Outline of lighting instructions
            for a propane-fired portable emergency use
            heater system equipped with continuous pilots
    Annex D (normative) - Outline of operating instructions
            for heater systems equipped with intermittent
            pilot or interrupted pilot systems
    Annex E (normative) - Outline of operating instructions
            for emergency use heater systems equipped with
            direct ignition systems
    Annex F (informative) - Relationship of carbon dioxide
            to oxygen in the closed room test specified in
            Clause 5.12 of this Standard
    Annex G (informative) - Pertinent references to ANSI Y14.15
    Annex H (informative) - Wire color designations
    Annex I (informative) - Recommended wire color usage
    Annex J (informative) - Preferred graphic symbols of
            commonly used items, extracted from Standard
            ANSI/IEEE 315, Graphic symbols for electrical
            and electronics diagrams, and abbreviations for
            these items
    Annex K (informative) - Table of conversion factors

    Abstract - (Show below) - (Hide below)

    This Standard applies to newly produced unvented, propane-fired portable emergency use heater systems utilizing a self-contained propane supply in a listed composite cylinder.

    Scope - (Show below) - (Hide below)

    Preface This is the second edition of ANSI Z21.11.3, Gas-fired room heaters, volume III, propane-fired emergency use heater systems. It supersedes the previous edition published in 2013. Scope 1.1 This Standard applies to newly produced unvented, propane-fired portable emergency use heater systems utilizing a self-contained propane supply in a listed composite cylinder. This appliance is not for use with line voltage. A portable emergency use heater system is to be identified as a "heater system" when the coverage refers to the heating appliance and the listed composite cylinder. The term "heater" is used when identifying the appliance only. A propane-fired portable emergency use heater system is constructed entirely of new, unused parts and materials. Propane-fired portable emergency use heater systems have input ratings up to and including 15,000 Btu/hr (4 396 W). a) Heater systems listed for use in bedrooms (during emergencies) have a maximum input setting of 10,000 Btu/hr (2 931 W); and b) Heater systems listed for use in bathrooms (during emergencies) have a maximum input setting of 5,000 Btu/hr (1465 W). 1.2 The construction of the heater and heater system is covered under Clause 4. 1.3 The performance of the heater and heater system is covered under Clause 5. 1.4 A listed composite cylinder meets the requirements of the U.S. Department of Transportation (DOT) special permit approval process* and is equipped with a listed overfilling prevention device (OPD) cylinder valve with a Compressed Gas Association CGA 793 male outlet connection. * Title 49 Code of Federal Regulations, Transportation, Part 178, Specifications for Packagings: Subpart H %u2013 Specifications for Portable Tanks; and Part 451, Testing and Approval of Containers. 1.5 A listed composite cylinder also meets the requirements of the Propane Education and Research Council (PERC) Fire Test* for indoor use during emergencies. * Code Approval of Composite Propane Cylinders for Indoor Use - PERC Docket 11643. 1.6 This Standard covers heater systems shipped from the factory equipped specifically for one gas only. Field conversion of gas types is not permitted. 1.7 Propane-fired portable emergency use heating systems are designed for indoor heating in buildings during emergencies. 1.8 If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.9 All references to psi throughout this Standard are to be considered gauge pressure unless otherwise specified. 1.10 Clause 2contains a list of standards referenced in this Standard and sources from which these standards may be obtained. 1.11 This Standard contains SI (Metric) corresponding to the yard/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. (Standard for use of the International System of Units (SI): The Modern Metric System, IEEE/ASTM SI 10 or ISO 80000-1:2009 Quantities and units Part 1: General are used as a guide in making metric conversion from yard/pound quantities.) If a value for a measurement and a corresponding value in other units are stated, the first stated value is to be regarded as the requirement. The given corresponding value may be approximate. If a value for a measurement and a corresponding value in other units are both specified as a quoted marking requirement, the first stated unit, or both shall be provided. 1.12 In this Standard, "shall" is used to express a requirement, i.e. a provision that the user is obliged to satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Canadian Standards Association
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ANSI Z21.21 : 2015 AUTOMATIC VALVES FOR GAS APPLIANCES
    NFPA 58 : 2017 LIQUEFIED PETROLEUM GAS CODE
    UL 1769:5ED 2015-06 Cylinder Valves
    CSA 6.5 : 2015 AUTOMATIC VALVES FOR GAS APPLIANCES
    ASME B18.6.4 : 1998 THREAD FORMING AND THREAD CUTTING TAPPING SCREWS AND METALLIC DRIVE SCREWS, INCH SERIES
    ASME B18.6.2 : 1998 SLOTTED HEAD CAP SCREWS, SQAURE HEAD SET SCREWS, AND SLOTTED HEADLESS SET SCREWS (INCH SERIES)
    ASME PTC19.3 : 1974(R2004) PERFORMANCE TEST CODE - PART 3: TEMPERATURE MEASUREMENT
    UL 2061:3ED 2015-07 Standard for Adapters and Cylinder Connection Devices for Portable LP-Gas Cylinder Assemblies
    IEEE 315 : 1975 GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS)
    ASME B1.20.1 : 2013(R2018) PIPE THREADS, GENERAL PURPOSE (INCH)
    CSA 6.10 : 2015 CONNECTORS FOR GAS APPLIANCES
    ASME B36.10M : 2015 WELDED AND SEAMLESS WROUGHT STEEL PIPE
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    NFPA 54 : 2018 NATIONAL FUEL GAS CODE
    UL 569:8ED 2013-11 Pigtails and Flexible Hose Connectors for LP-Gas
    ANSI Z223.1 : 2018 NATIONAL FUEL GAS CODE
    ANSI Z21.24 : 2015 CONNECTORS FOR GAS APPLIANCES
    ASME B18.6.3 : 2013 MACHINE SCREWS, TAPPING SCREWS, AND METALLIC DRIVE SCREWS (INCH SERIES)
    UL 2227:2ED 2007-02 Standard for Overfilling Prevention Devices
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective