API 2517D : 1ED 93
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
DOCUMENTATION FILE FOR API 2517 - EVAPORATION LOSS FROM EXTERNAL FLOATING-ROOF TANKS
12-12-2018
12-01-2013
List of Tables
List of Figures
Nomenclature
1.0 Introduction
2.0 Roof-Fitting Loss Factors
2.1 Measurement of Roof-Fitting Losses
2.2 Roof Fittings Tested
2.3 Analysis of Roof-Fitting Loss Data
2.4 Development of Roof-Fitting Loss Factors Kfa, Kfb
and m
2.5 Total Roof-Fitting Loss Factor, Ff for Typical
Pontoon and Double-Deck Floating Roofs
3.0 Typical Number of Roof Fittings
3.1 Typical Number of Roof Legs
3.2 Typical Number of Vacuum Breakers
3.3 Typical Number of Roof Drains
4.0 References
Tables
Figures
List of Tables
1. Summary of Test Numbers and Test Conditions
2. Summary of Test Results for the 8-inch Diameter
Slotted Gage Pole and Well
3. Summary of Test Results for the 15-inch Diameter
Covered Well
4. Summary of Test Results for the 6-inch Diameter Open
Drain
5. Summary of Test Results for the Roof Legs
6. Roof-Fitting Loss Factors for Access Hatches, Gauge-
Float Wells, Gauge-Hatch/Sample Wells, Vacuum
Breakers and Rim Vents
7. Roof-Fitting Loss Factors for Roof Drains
8. Roof-Fitting Loss Factors for Slotted Guide-Pole/
Sample Wells and Unslotted Guide-Pole Wells
9. Roof-Fitting Loss Factors for Roof Legs
10. Roof-Fitting Loss Factors, Kfa, Kfb and m
11. Number of Roof-Fittings for Typical Pontoon Floating
Roofs
12. Number of Roof-Fittings for Typical Double-Deck
Floating Roofs
13. Total Roof-Fitting Loss Factor, Ff, for Typical
Pontoon Floating Roofs
14. Total Roof-Fitting Loss Factor, Ff, for Typical
Double-Deck Floating Roofs
15. Total Roof-Fitting Loss Factor Coefficients for
Typical Pontoon Floating Roofs
16. Total Roof-Fitting Loss Factor Coefficients for
Typical Double-Deck Floating Roofs
17. Number of Roof Legs for Tank Manufacturer Number 1
18. Number of Roof Legs for Tank Manufacturer Number 2
19. Number of Roof Legs for Tank Manufacturer Number 3
20. Average Number of Roof Legs for Tank Manufacturer
Numbers 1, 2 and 3
21. Typical Number of Roof Legs
22. Number and Diameter of Vacuum Breakers for Tank
Manufacturer Number 1
23. Number and Diameter of Vacuum Breakers for Tank
Manufacturer Number 2
24. Average Number and Diameter of Vacuum Breakers for
Tank Manufacturer Numbers 1 and 2
25. Typical Number of Vacuum Breakers
26. Number and Diameter of Roof Drains for Double-Deck
Roofs for Tank Manufacturer Numbers 1 and 2
27. Typical Number of Roof Drains for Double-Deck Roofs
List of Figures
1. Wind Tunnel Test Facility
2. Roof-Fitting Loss Factor for a Covered Well
(15-inch diameter well)
3. Roof-Fitting Loss Factor for a Roof Drain
(6-inch diameter), Open
4. Roof-Fitting Loss Factor for a Roof Drain
(6-inch diameter), 90% Closed
5. Roof-fitting Loss Factor for a Slotted Guide-Pole/
Sample Well (8-inch diameter slotted pole, 21-inch
diameter well), Gasketed Sliding Cover, With Float
6. Roof-Fitting Loss Factor for a Slotted Guide-Pole/
Sample Well (8-inch diameter slotted pole, 21-inch
diameter well), Ungasketed Sliding Cover, with Float
7. Roof-Fitting Loss Factor for a Slotted Guide-Pole/
Sample Well (8-inch diameter slotted pole, 21-inch
diameter well), Ungasketed Sliding Cover, Without
Float
8. Roof-Fitting Loss Factor for a Roof Leg (3-inch
diameter), Adjustable, Pontoon Area
9. Roof-Fitting Loss Factor for a Roof Leg (3-inch
diameter), Adjustable, Center Area and Double-Deck
Roofs
10. Roof-Fitting Loss Factor for a Roof Leg (2.5 inch
diameter), Adjustable, Pontoon Area
11. Total Roof-Fitting Loss Factor for Typical Fittings
on a Pontoon Floating Roof
12. Total Roof-Fitting Loss Factor for Typical Fittings
on a Double-Deck Floating Roof
13. Number of Pontoon Roof Legs for a Pontoon Floating
Roof
14. Number of Center Area Roof Legs for a Pontoon
Floating Roof
15. Total Number of Roof Legs for a Pontoon Floating
Roof
16. Total Number of Roof Legs for a Double-Deck Floating
Roof
17. Number of Vacuum Breakers for a Pontoon Floating
Roof
18. Number of Vacuum Breakers for a Double-Deck Floating
Roof
19. Number of Roof Drains for a Double-Deck Floating
Roof
DocumentType |
Standard
|
PublisherName |
American Petroleum Institute
|
Status |
Withdrawn
|
API MPMS CHAPTER 19.3 PART H : 1998(R2009) | MANUAL OF PETROLEUM MEASUREMENT STANDARDS - CHAPTER 19.3: EVAPORATIVE LOSS MEASUREMENT - PART H: TANK SEALS AND FITTING CERTIFICATION - ADMINISTRATION |
API MPM CH19.3A : 1997(R2012) | MANUAL OF PETROLEUM MEASUREMENT STANDARDS - CHAPTER 19.3 - EVAPORATIVE LOSS MEASUREMENT - PART A - WIND TUNNEL TEST METHOD FOR THE MEASUREMENT OF DECK-FITTING LOSS FACTORS FOR EXTERNAL FLOATING-ROOF TANKS |
API MPM CH19.3A : 1997 | MANUAL OF PETROLEUM MEASUREMENT STANDARDS - CHAPTER 19.3 - EVAPORATIVE LOSS MEASUREMENT - PART A - WIND TUNNEL TEST METHOD FOR THE MEASUREMENT OF DECK-FITTING LOSS FACTORS FOR EXTERNAL FLOATING-ROOF TANKS |
API MPM CH19.3H:1998 | MANUAL OF PETROLEUM MEASUREMENT STANDARDS - CHAPTER 19.3: EVAPORATIVE LOSS MEASUREMENT - PART H: TANK SEALS AND FITTING CERTIFICATION - ADMINISTRATION |
API MPM CH19.2 : 2012 | MANUAL OF PETROLEUM MEASUREMENT STANDARDS - CHAPTER 19.2: EVAPORATIVE LOSS FROM FLOATING-ROOF TANKS |
API MPM CH19.3A : 1997 : R2007 | MANUAL OF PETROLEUM MEASUREMENT STANDARDS - CHAPTER 19.3 - EVAPORATIVE LOSS MEASUREMENT - PART A - WIND TUNNEL TEST METHOD FOR THE MEASUREMENT OF DECK-FITTING LOSS FACTORS FOR EXTERNAL FLOATING-ROOF TANKS |
API 2519 : 3ED 83(R1996) | EVAPORATION LOSS FROM INTERNAL FLOATING-ROOF TANKS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.