API 632 : 1ED 88
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
WINTERIZATION OF AIR COOLED HEAT EXCHANGERS
23-07-2013
12-01-2013
Section 1 - General
1.1 Scope
1.2 Definition of terms
1.3 Referenced publications
Section 2 - Winterization problem areas
2.1 General
2.2 Reasons for winterization
2.3 General design data requirements
2.4 Heat losses
2.5 General problem areas
2.6 Process categories
2.7 Safety margins
Section 3 - Methods of winterization
3.1 Airflow and air temperature control systems
3.2 Cocurrent flow
3.3 Bare tubes or reduced fin density
3.4 Varying the active heat transfer surface
3.5 Serpentine coils
3.6 Indirect cooling
3.7 Duty separation
3.8 Combinations
3.9 Instrumentation
Section 4 - Critical process temperatures
4.1 Pour points of hydrocarbon liquid mixtures
4.2 Freezing points of hydrocarbons and other organic
liquid pure compounds
4.3 Water solutions of organic compounds
4.4 Ammonium bisulfide
4.5 High-pressure gases
4.6 References
Section 5 - Tube wall temperature calculations
5.1 General
5.2 Nomenclature
5.3 Calculations
5.4 References
Section 6 - Heat losses
6.1 General
6.2 Louver leakage
6.3 Surface heat loss
Section 7 - Guidelines for sizing air ducts
7.1 General
7.2 Design methods
Section 8 - Mechanical equipment
8.1 General
8.2 Design temperatures
8.3 Design temperature range
8.4 Typical characteristics and operating ranges for
standard mechanical equipment
8.5 Auxiliary heating equipment
Section 9 - Start-up and shutdown procedures
9.1 General
9.2 Start-up procedures
9.3 Shutdown procedures
Appendix A - Sample economic comparison of indirect
(tempered-water) versus direct air cooling
for systems requiring winterization
Appendix B - Calculation of minimum tube wall
temperature
Appendix C - Sample calculation of heat losses
Figures
1 System A: Airflow control with automatically
controlled variable-pitch fans
2 System A: Airflow control with automatically
controlled outlet louvers and fixed-pitch fans
3 System B: Induced draft with noncontained internal
air recirculation
4 System B: Forced draft with noncontained internal
air recirculation
5 System C: Typical forced-draft air-cooled heat
exchanger with contained internal air
recirculation
6 System D: Typical forced-draft air-cooled heat
exchanger with external air recirculation
7 Freezing points of phenol-water solutions
8 Freezing points of ethanolamine-water solutions
9 Freezing points of glycerol-water solutions
10 Dissociation constant of ammonium bisulfide
(NH4HS)
11 Hydrate pressure-temperature equilibria
A-1 Tempered-water system
Tables
1 Safety margins for different process categories
2 Freezing points of frequently encountered liquid
pure compounds
A-1A Description of indirect and direct air cooling
systems (customary units)
A-1B Description of indirect and direct air cooling
systems (SI units)
A-2 Comparison of costs of indirect and direct air
cooling systems
B-1A Values for rm referred to the total outside area
for a tube with an outside diameter of 1 inch and
aluminium fins
B-1B Values for rm referred to the total outside area
for a tube with an outside diameter of 25.4
millimeters and aluminium fins 15.9 millimeters
high and 0.4 millimeters thick (SI units)
Recommends design features and other considerations to give satisfactory operation of air cooled heat exchangers with low temperature inlet air. Coverage includes: reasons for winterization; general design data requirements; general problem areas; airflow and air temperature control systems; bare tubes or reduced fin density; varying the active heat transfer surface; pour points of hydrocarbon liquid mixtures; freezing points of hydrocarbons and other organic liquid pure compounds; high pressure gases; water solutions of organic compounds; typical characteristics and operating ranges for standard mechanical equipment; auxiliary heating equipment. Also gives detailed tables, diagrams and appendices.
DocumentType |
Standard
|
PublisherName |
American Petroleum Institute
|
Status |
Withdrawn
|
API 661 : 2015 | PETROLEUM, PETROCHEMICAL, AND NATURAL GAS INDUSTRIES - AIR-COOLED HEAT EXCHANGERS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.