• There are no items in your cart

API 937 : 1996

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

EVALUATION OF DESIGN CRITERIA FOR STORAGE TANKS WITH FRANGIBLE ROOF JOINTS

Available format(s)

Hardcopy , PDF

Withdrawn date

15-06-2010

Language(s)

English

Published date

01-04-1996

€140.88
Excluding VAT

1.0 Introduction
2.0 Background Information
      2.1 Description of Typical Tank Design
      2.2 API 650 Design Rules for Frangible Roofs
      2.3 Derivation of API 650 Rules
      2.4 Derivation of Wc and Wh in API 650 Design
           Rules
           2.4.1 Derivation of Wc
           2.4.2 Derivation of Wh
      2.5 Summary of Frangible Joint Study by British
           Researchers
3.0 Combustion Analysis
      3.1 Combustion Wave Geometry
      3.2 Combustion Calculation
           3.2.1 Flame Temperature Calculation
           3.2.2 Burning Velocity
           3.2.3 Calculation of Pressure Rise
      3.3 Venting
      3.4 Pressure Sensitivity Study
           3.4.1 Effect of Ignition Source Location
           3.4.2 Effect of Tank Size on Pressure Rise
           3.4.3 Effect of Different Fuels and Air-to-
                  Fuel Ratios
4.0 Structural Analysis
      4.1 Scoping Analyses of Full Scale Tanks
           4.1.1 Static Stresses at the Roof-to-Shell
                  Joint
           4.1.2 Axisymmetric Modal Analysis
           4.1.3 Elastic Buckling Analysis
      4.2 Analyses of Model Tanks Tested Dynamically
           4.2.1 Axisymmetric Large Displacement
                  Static Analysis
           4.2.2 Axisymmetric Large Displacement
                  Dynamic Analysis
           4.2.3 3-D Large Displacement Analysis
           4.2.4 Analysis of Stitch Welded Tank
      4.3 Analyses of Small Model Tanks
5.0 Testing
      5.1 Joint Details
      5.2 Static Test of Small Scale Model Tanks
      5.3 Dynamic Test of Model Tanks
           5.3.1 Objectives
           5.3.2 Design of Model Tanks
           5.3.3 Test Description
           5.3.4 Results of Testing
6.0 API-Tank: A Program for the Design/Analysis of
      Tanks with Frangible Roof Joints
      6.1 Automatic Design
      6.2 Structural Analysis
      6.3 Nonlinear Solution Procedure
      6.4 Combustion Calculation Procedure
      6.5 Frangible Joint Failure
      6.6 Verification
7.0 Evaluation of Tanks
8.0 Conclusions
8.0 References
9.0 Acknowledgements
Appendix A: List of Ansys files for verification
      A.1 Input File for Example Tank 1
      A.2 Input File for Example Tank 2

Describes research that evaluates the ability of the present API 650 tank design criteria to ensure the desired frangible joint behavior. Particular questions include: (1) evaluation of the area inequality as a method to predict the buckling response of the compression ring, (2) effect of roof slope, tank diameter, and weld size on the frangible joint, and (3) effect of the relative strength of the roof-to-shell joint compared to the shell-to-bottom joint.

DocumentType
Standard
Pages
80
ProductNote
This product is unavailable in Cuba, Iran, North Korea, Syria
PublisherName
American Petroleum Institute
Status
Withdrawn

API 650 : 2013 WELDED TANKS FOR OIL STORAGE
API 2000 : 2014 VENTING ATMOSPHERIC AND LOW-PRESSURE STORAGE TANKS
API 9100B : 1998 GUIDANCE DOCUMENT FOR MODEL EHS MANAGEMENT SYSTEM
API 650 : 2013+ADD 3 : 2018 WELDED TANKS FOR OIL STORAGE
API 650 CHINESE : 2013 WELDED TANKS FOR OIL STORAGE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.