01-01-2015
1.0 INTRODUCTION
1.1 U.S. Customary And Metric (Si) Units
1.2 National Weights and Measures Agencies
1.3 Safety Considerations
2.0 SCOPE
3.0 REFERENCE PUBLICATIONS
4.0 TERMS AND APPLICATIONS
4.1 TERMS
4.2 APPLICATIONS
5.0 PROVER CLEANING AND PREPARATION
5.1 Isolation of the Prover
5.2 Initial Prover Preparation
5.3 Purging and Cleaning of the Prover
5.4 Sphere Displacer Inspection, Sizing and Preparation
5.5 Water Filling, Venting and Circulation of Pipe Provers
6.0 PRELIMINARY AND GENERAL CALIBRATION PROCEDURES
6.1 General Calibration Discussion
6.2 Displacement Type Unidirectional Provers with Free
Displacers
6.3 Displacement Type Bi-directional Provers with Free
Displacers
6.4 Displacement Type Meter Provers with Captive Displacers
6.5 Atmospheric Tank Provers
7.0 CALIBRATION PROCEDURES BY TYPE OF PROVER
7.1 Calibration Preparation
7.2 Displacement Type Unidirectional Provers with Free
Displacers
7.3 Displacement Type Bi-directional Provers with Free
Displacers
7.4 Displacement Type Meter Provers with Captive Displacers
7.5 Atmospheric Tank Provers
8.0 TROUBLESHOOTING CALIBRATION PROBLEMS
8.1 Evaluation of Calibration Results
8.2 Leaks
8.3 Prover Detector Switches
8.4 Sphere Interchanges
8.5 Four-Way Valves
8.6 Displacers
8.7 Drains and Vents
8.8 Temperature and Pressure
8.9 Pumps, Hoses and Connections
8.10 Detector Switches, Solenoids and Logic Circuits
8.11 Field Standard Test Measures
8.12 Piping and Manifolds
8.13 Water Quality
8.14 Air and Entrained Gas
8.15 Prover Conditions and Coatings
APPENDIX A (INFORMATIVE) UNCERTAINTIES IN METER PROVER
CALIBRATIONS
APPENDIX B (NORMATIVE) EFFECTS OF TEMPERATURE CHANGES ON THE
INTERFACE INVENTORY
APPENDIX C (INFORMATIVE) EXAMPLES OF WATERDRAW DATA SHEETS
APPENDIX D (INFORMATIVE) FIELD STANDARD TEST MEASURES
Figures
Tables
Describes all the procedures required to determine the field data necessary to calculate a Base Prover Volume (BPV), of either Displacement Provers or Volumetric Tank Provers, by the Waterdraw Method of Calibration.
DocumentType |
Standard
|
Pages |
104
|
ProductNote |
Reconfirmed 2005
|
PublisherName |
American Petroleum Institute
|
Status |
Superseded
|
SupersededBy |
API MPM CH7 : 2001 | MANUAL OF PETROLEUM MEASUREMENT STANDARDS - CHAPTER 7 - TEMPERATUREDETERMINATION |
API MPM CH4 : 1ED 78 | PROVING SYSTEMS |
API MPM CH1 : 1994 | Manual of Petroleum Measurement Standards - Chapter 1: Vocabulary |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.