1 - AS 1038.2-1995 COAL AND COKE - ANALYSIS AND TESTING - COKE - TOTAL MOISTURE
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 REFERENCED DOCUMENTS
6 - 3 DEFINITIONS
6 - 3.1 Coke
6 - 3.2 Common sample
6 - 3.3 Free moisture
6 - 3.4 Gross sample
6 - 3.5 Moisture sample
6 - 3.6 Residual moisture (moisture in the air-dry sample)
6 - 3.7 Total moisture
7 - 4 SAFETY
7 - 5 SAMPLES
7 - 5.1 General
7 - 5.2 Types of samples to be tested
7 - 5.3 Precautions against loss of moisture
7 - 5.4 As-received samples
7 - 6 DETERMINATION OF FREE MOISTURE
7 - 6.1 Principle
8 - 6.2 Apparatus
8 - 6.3 Drying time
8 - 6.4 Procedure
8 - 6.5 Calculation of result
9 - 7 DETERMINATION OF RESIDUAL MOISTURE (MOISTURE IN THE AIR-DRY SAMPLE)
9 - 7.1 Principle
9 - 7.2 Apparatus
9 - 7.3 Procedure
9 - 7.4 Calculation
10 - 8 CALCULATION OF TOTAL MOISTURE
10 - 8.1 Sample air-dried
10 - 8.2 Sample not air-dried
10 - 9 PRECISION
10 - 10 REPORTING OF RESULTS
10 - 11 TEST REPORT
11 - APPENDIX A - PREFERRED SCHEME FOR DETERMINATION OF TOTAL MOISTURE

Sets out methods for the determination of total moisture, free moisture and residual moisture in coke.

Committee
MN-001
DocumentType
Standard
ISBN
0 7262 9599 X
Pages
6
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out methods for the determination of total moisture, free moisture and residual moisture in coke. The methods are as follows:(a) Drying in air, for free moisture.(b) Drying in air, for residual moisture.Where the sample is visibly wet, determination of residual moisture is generally preceded by the determination of free moisture, unless the sample is suitable for the direct determination at total moisture.

First published as part of AS CK2.3-1949.
Revised and redesignated in part as AS K152.2-1965.
AS K152.2 withdrawn 1978.
Revised and redesignated AS 1038.2-1979.
Second edition 1995.

AS 2418-1995 Coal and coke - Glossary of terms (Reconfirmed 2013) (Reconfirmed 2023)
AS 1038.16-1996 Coal and coke - Analysis and testing - Assessment and reporting of results
AS 2646.7-1985 Sampling of solid mineral fuels Coke - Preparation of samples
AS 2706-1984 Numerical values - Rounding and interpretation of limiting values

AS 3899-1991 Higher rank coal and coke - Bulk density
AS 1038.16-2005 Coal and coke - Analysis and testing Assessment and reporting of results (Reconfirmed 2016)
AS 1038.16-1996 Coal and coke - Analysis and testing - Assessment and reporting of results
AS 3899-2002 Higher rank coal and coke - Bulk density (Reconfirmed 2013) (Reconfirmed 2023)
AS 4264.2-1996 Coal and coke - Sampling Coke - Sampling procedures (Reconfirmed 2013)
AS 2418-1995 Coal and coke - Glossary of terms (Reconfirmed 2013) (Reconfirmed 2023)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.