1 - AS 1284.6-1992 ELECTRICITY METERING - RIPPLE CONTROL RECEIVERS FOR TARIFF AND LOAD CONTROL
4 - PREFACE
6 - CONTENTS
7 - FOREWORD
8 - 1 Scope
8 - 2 Normative references
10 - 3 Definitions
10 - 3.1 General definitions
10 - 3.2 Definitions related to the functional elements
12 - 3.3 Definitions of mechanical elements
12 - 3.4 Definitions of insulations
13 - 3.5 Definitions of influence quantities
14 - 3.6 Definition of tests
14 - 4 Requirements
14 - 4.1 Standard electrical values
14 - 4.1.1 Rated supply voltage
14 - 4.1.2 Rated supply frequency
14 - 4.2 Mechanical requirements
14 - 4.2.1 General mechanical requirements
14 - 4.2.2 Case
15 - 4.2.3 Terminals, terminal block(s), protective earth terminal
16 - 4.2.4 Terminal cover(s)
16 - 4.2.5 Clearance and creepage distances
17 - 4.2.6 Resistance to heat and fire
17 - 4.2.7 Protection against penetration of dust and water
17 - 4.2.8 Marking of receiver
17 - 4.2.9 Operation status indicator
18 - 4.3 Climatic conditions
18 - 4.3.1 Temperature range
18 - 4.3.2 Relative humidity
18 - 4.4 Electrical requirements
18 - 4.4.1 Power consumption
19 - 4.4.2 Supply voltage range
19 - 4.4.3 Effect of long interruptions of supply voltage
19 - 4.4.4 Rated breaking voltage
19 - 4.4.5 Rated breaking current
20 - 4.4.6 Number of operations of the output element
20 - 4.4.7 Short-circuit performance of the output element
20 - 4.4.8 Heating
20 - 4.4.9 Insulation
21 - 4.5 Control voltage requirements
21 - 4.5.1 Operate voltage
21 - 4.5.2 Non-operate voltage
21 - 4.5.3 Maximum control voltage
21 - 4.5.4 Tolerance on the message
22 - 4.6 Electromagnetic compatibility (EMC)
22 - 4.6.1 Immunity to electromagnetic disturbance
22 - 4.6.2 Harmonics
22 - 4.6.3 Interharmonics (quasi-steady voltages of non harmonic frequencies).
23 - 4.6.4 Disturbing pulses
23 - 4.6.5 Voltage dips and short interruptions
23 - 4.7 Radio interference suppression
24 - 5 Tests and test conditions
24 - 5.1 General testing procedures
24 - 5.1.1 Test conditions
24 - 5.1.2 Type test
24 - 5.2 Tests of mechanical requirements
24 - 5.2.1 Spring hammer test
24 - 5.2.2 Shock test
25 - 5.2.3 Vibration test
25 - 5.2.4 Test of resistance to heat and fire
25 - 5.2.5 Test of protection against penetration of dust and water
26 - 5.3 Test of climatic influences
26 - 5.3.1 Dry heat test
26 - 5.3.2 Cold test
26 - 5.3.3 Damp heat cyclic test
26 - 5.4 Test of electrical requirements
26 - 5.4.1 Test of power consumption
26 - 5.4.2 Test of effect of a long interruption of the supply voltage
27 - 5.4.3 Test on number of operations of the output element
27 - 5.4.4 Test of short-circuit performance of the output element
28 - 5.4.5 Test of influence of heating
28 - 5.4.6 Test of insulation properties
29 - 5.5 Test of control performance requirements
29 - 5.5.1 General test conditions
30 - 5.5.2 Test of operation
30 - 5.5.3 Test of non-operation
30 - 5.5.4 Test of correct receiver operation within the tolerance of the message
30 - 5.6 Tests for electromagnetic compatibility
30 - 5.6.1 General test conditions
30 - 5.6.2 Test of influence of interharmonics (quasi-steady disturbing voltages of non harmonic frequencies)
31 - 5.6.3 Test of effect of disturbing pulses on operation
32 - 5.6.4 Test of effect of short interruptions of supply and voltage dips in operation
33 - 5.6.5 Test of immunity to electrostatic discharges
33 - 5.6.6 Test of immunity to HF electromagnetic fields
33 - 5.6.7 Fast transient burst test
34 - 5.6.8 Test of immunity to d.c. magnetic fields
34 - 5.6.9 Test of immunity to a.c. magnetic fields
34 - 5.7 Radio interference measurement
46 - APPENDIX AA - VARIATIONS TO IEC 1037 FOR AUSTRALIA
46 - AA1 SCOPE
46 - AA2 NORMATIVE REFERENCES
46 - AA3 DEFINITIONS (ADDITION)
46 - AA4 INSULATION ENCASED RECEIVER OF PROTECTIVE CLASS II
46 - AA5 RATED SUPPLY VOLTAGE
46 - AA6 RATED SUPPLY FREQUENCY
46 - AA7 CASE
47 - AA8 TERMINALS, TERMINAL BLOCK(S), PROTECTIVE EARTH TERMINAL
47 - AA9 TERMINAL COVER(S)
47 - AA10 CLEARANCE AND CREEPAGE DISTANCES
47 - AA11 PROTECTION AGAINST PENETRATION OF DUST AND WATER
47 - AA12 NAMEPLATES
47 - AA13 OPERATION STATUS INDICATOR
48 - AA14 MECHANICAL REQUIREMENTS
48 - AA15 TEMPERATURE RANGE
48 - AA16 RELATIVE HUMIDITY
48 - AA17 POWER CONSUMPTION
48 - AA18 SUPPLY VOLTAGE RANGE
48 - AA19 EFFECT OF LONG INTERRUPTIONS OF SUPPLY VOLTAGE
48 - AA20 EFFECT OF SHORT-TIME OVERVOLTAGES
48 - AA21 RATED BREAKING VOLTAGE
49 - AA22 RATED BREAKING CURRENT
49 - AA23 HEATING
49 - AA24 SPRING HAMMER TEST
49 - AA25 TEST OF RESISTANCE TO HEAT AND FIRE
49 - AA26 TEST OF PROTECTION AGAINST PENETRATION OF DUST AND WATER
49 - AA27 DRY HEAT TEST
49 - AA28 DAMP HEAT CYCLIC TEST
49 - AA29 SOLAR RADIATION TEST (ADDITION)
49 - AA30 TEST ON NUMBER OF OPERATIONS OF THE OUTPUT ELEMENT
49 - AA31 TEST OF INFLUENCE OF HEATING
50 - AA32 IMPULSE VOLTAGE TEST
50 - AA33 RELATIONSHIP BETWEEN AMBIENT AIR TEMPERATURE AND RELATIVE HUMIDITY
50 - AA34 REFERENCE AND LIMITING VALUES OF THE INFLUENCE QUANTITIES
50 - AA35 COMBINATION OF PARAMETERS FOR OPERATION AND NON-OPERATION TESTS
50 - AA36 ACCEPTANCE TESTS
50 - AA37 EXAMPLE OF A TEST CONFIGURATION
50 - AA38 VALUES OF THE INFLUENCE QUANTITIES FOR THE DIFFERENT TESTS