AS 1289.3.8.3-1997
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Methods of testing soils for engineering purposes Soil classification tests - Dispersion - Determination of pinhole dispersion classification of a soil
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
24-07-2024
01-01-1997
This Standard sets out the method for the determination of pinhole dispersion classification of a compacted fine-grained soil.
Committee |
CE-009
|
DocumentType |
Standard
|
ISBN |
0 7337 1091 3
|
Pages |
6
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out the method for the determination of pinhole dispersion classification of a compacted fine-grained soil. The test is carried out on the portion of soil passing the 2.36 mm aperture sieve and using either local, tap or distilled water.
First published as AS 1289.C8.3-1984.
Revised and redesignated AS 1289.3.8.3-1997.
AS 1289.5.1.1-1993 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using standard compactive effort |
AS 1289.2.1.1-1992 | Methods of testing soils for engineering purposes Soil moisture content tests - Determination of the moisture content of a soil - Oven drying method (standard method) |
AS 1289.5.4.1-1993 | Methods of testing soils for engineering purposes Soil compaction and density tests - Compaction control test - Dry density ratio, moisture variation and moisture ratio |
AS 1289.0-1991 | Methods of testing soils for engineering purposes General requirements and list of methods |
AS 1152-1993 | Specification for test sieves |
AS 1289.3.2.1-1995 | Methods of testing soils for engineering purposes Soil classification tests - Determination of the plastic limit of a soil - Standard method |
AS 1597.2-2013 | Precast reinforced concrete box culverts Large culverts (exceeding 1200 mm span or 1200 mm height and up to and including 4200 mm span and 4200 mm height) |
HB 160-2006 | Soils testing |
AS/NZS 3725:2007 | Design for installation of buried concrete pipes |
AS 4799-2000 | Installation of underground utility services and pipelines within railway boundaries |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.