• AS 1306-1985

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    High voltage a.c. switchgear and controlgear - Disconnectors (isolators) and earthing switches

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  30-06-2017

    Language(s):  English

    Published date:  01-01-1985

    Publisher:  Standards Australia

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 - AS 1306-1985 HIGH VOLTAGE A.C. SWITCHGEAR AND CONTROLGEAR - DISCONNECTORS (ISOLATORS) AND EARTHING SWITCHES
    4 - PREFACE
    5 - CONTENTS
    7 - 1. SCOPE AND GENERAL
    7 - 1.1 SCOPE.
    7 - 1.2 APPLICATION.
    7 - 1.3 REFERENCED DOCUMENTS.
    7 - 2. SERVICE CONDITIONS
    7 - 3. DEFINITIONS
    7 - 3.1 GENERAL.
    7 - 3.101 GENERAL TERMS.
    7 - 3.101.1 Switchgear and controlgear
    7 - 3.101.2 Ambient air temperature
    7 - 3.101.3 Temperature rise
    7 - 3.102 SWITCHING DEVICES.
    7 - 3.102.1 Disconnector
    7 - 3.102.2 Divided support disconnector
    7 - 3.102.3 Centre-break disconnector
    8 - 3.102.4 Double-break disconnector
    8 - 3.102.5 Earthing switch
    8 - 3.103 PARTS OF SWITCHING DEVICES.
    8 - 3.103.1 Contact (of a mechanical switching device)
    8 - 3.103.2 Contact piece
    8 - 3.103.3 Position indicating device
    8 - 3.103.4 Position signalling device
    8 - 3.103.5 Terminal
    8 - 3.103.6 Contact zone
    8 - 3.104 CHARACTERISTIC QUANTITIES.
    8 - 3.104.1 Prospective peak current
    8 - 3.104.2 (Peak) Making current (of an earthing switch
    8 - 3.104.3 Peak current
    8 - 3.104.4 Normal current (of a disconnector)
    8 - 3.104.5 Permissible duration of short-circuit current
    8 - 3.104.6 Peak withstand current
    8 - 3.104.7 Rated value
    8 - 3.104.8 Rated insulation level
    8 - 3.104.9 Rated 1-minute power-frequency withstand voltage
    8 - 3.104.10 Rated impulse withstand voltage
    8 - 3.104.11 Clearance between open contacts (gap)
    8 - 3.104.12 Clearance to earth
    8 - 3.104.13 Mechanical terminal load
    8 - 4. RATINGS
    8 - 4.0 LIST OF RATINGS.
    9 - 4.1 RATED VOLTAGE.
    9 - 4.2 RATED INSULATION LEVEL.
    9 - 4.3 RATED FREQUENCY.
    9 - 4.4 RATED NORMAL CURRENT AND TEMPERATURE-RISE
    9 - 4.5 RATED SHORT-TIME WITHSTAND CURRENT
    9 - 4.6 RATED PEAK WITHSTAND CURRENT.
    9 - 4.7 RATED DURATION OF SHORT-CIRCUIT.
    9 - 4.8 RATED SUPPLY VOLTAGE OF CLOSING AND OPENING DEVICES AND AUXILIARY CIRCUITS
    9 - 4.9 RATED SUPPLY FREQUENCY OF OPERATING DEVICES AND AUXILIARY CIRCUITS.
    9 - 4.10 RATED PRESSUREOF COMPRESSED GAS SUPPLY FOR OPERATION
    9 - 4.11 RATED MECHANICAL LOAD OF TERMINALS
    11 - 4.101 RATED SHORT-CIRCUIT MAKING CURRENT
    11 - 4.102 RATED CONTACT ZONE.
    14 - 4.103 RATED VALUES OF MAXIMUM FORCE REQUIRED FOR MANUAL OPERATION
    14 - 4.104 BEHAVIOUR WHEN CARRYING RATED PEAK WITHSTAND CURRENT AND RATED SHORT-TIME WITHSTAND CURRENT.
    14 - 4.104.1 Disconnectors.
    14 - 4.104.2 Earthing switches.
    14 - 4.105 BEHAVIOUR OF EARTHING SWITCHES WHEN MAKING SHORT-CIRCUIT CURRENTS.
    14 - 4.106 COORDINATION OF RATED VOLTAGES, RATED NORMAL CURRENTS, AND RATED SHORT-TIME WITHSTAND CYURRENTS
    14 - 5. DESIGN AND CONSTRUCTION
    14 - 5.1 REQUIREMENTS FOR LIQUIDS.
    14 - 5.2 REQUIREMENTS FOR GASES.
    16 - 5.3 EARTHING.
    16 - 5.4 AUXILIARY EQUIPMENT.
    16 - 5.5 DEPENDENT POWER CLOSING-OPENING.
    16 - 5.6 STORED ENERGY CLOSING-OPENING.
    16 - 5.7 OPERATION OF RELEASES.
    16 - 5.8 LOW AND HIGH PRESSURE INTERLOCKING DEVICES
    16 - 5.9 NAMEPLATES.
    16 - 5.10 TERMINALS.
    16 - 5.11 POSITION INDICATING DEVICE.
    16 - 5.101 SPECIAL REQUIREMENTS FOR EARTHING SWITCHES
    16 - 5.102 LEAKAGE CURRENTS ACROSS OPEN DISCONNECTORS.
    16 - 5.103 MECHANICAL STRENGTH.
    16 - 5.104 POSITION OF MOVABLE CONTACT SYSTEM AND SIGNALLING.
    16 - 5.104.1 Securing of position.
    16 - 5.104.2 Auxiliary contacts for position signalling.
    16 - 5.105 MECHANICAL AND ELECTRICAL INTERLOCKS
    18 - 6. TYPE TESTS
    18 - 6.0 GENERAL.
    18 - 6.1 DIELECTRIC TESTS
    18 - 6.1.1 Ambient air conditions during tests.
    18 - 6.1.2 Wet test procedure.
    18 - 6.1.3 Conditions of disconnectors and earthing switches during tests
    18 - 6.1.4 Application of test voltage and test conditions.
    18 - 6.1.5 Test voltage.
    18 - 6.1.6 Lightning and switching impulse voltage tests.
    19 - 6.1.7 Power-frequency voltage withstand tests.
    19 - 6.1.8 Artificial pollution tests.
    19 - 6.1.9 Partial discharge tests.
    19 - 6.1.10 Test on auxiliary and control circuits.
    20 - 6.2 RADIO-INTERFERENCE VOLTAGE (RIV) TEST
    20 - 6.3 TEMPERATURE-RISE TESTS.
    20 - 6.4 MEASUREMENT OF RESISTANCE OF THE MAIN CIRCUIT
    20 - 6.5 SHORT-TIME WITHSTAND CURRENT AND PEAK WITHSTAND CURRENT TESTS
    20 - 6.5.1 Arrangements of the mechanical switching device and of the test circuit.
    20 - 6.101 TESTS TO PROVE THE SHORT-CIRCUIT MAKING CURRENT PERFORMANCE OF EARTHING SWITCHES
    20 - 6.102 TESTS TO PROVE SATISFACTORY OPERATION AND MECHANICAL ENDURANCE.
    20 - 6.102.1 General test conditions.
    24 - 6.102.2 Contact zone test.
    24 - 6.102.3 Mechanical endurance test.
    24 - 6.102.4 Verification of operation during application of rated mechanical terminals loads
    24 - 6.103 TESTS TO PROVE SATISFACTORY OPERATION UNDER SEVERE ICE CONDITIONS.
    24 - 6.103.1 Applicability of tests.
    24 - 6.103.2 Test arrangements.
    25 - 6.103.3 Test procedure.
    25 - 6.104 TESTS TO PROVE SATISFACTORY OPERATION AT MINIMUM AND MAXIMUM AMBIENT AIR TEMPERATURE.
    25 - 6.104.1 General.
    25 - 6.104.2 Operation at minimum ambient air temperature
    25 - 6.104.3 Operation at maximum ambient air temperature
    26 - 7. ROUTINE TESTS
    26 - 7.0 GENERAL.
    26 - 7.1 POWER-FREQUENCY VOLTAGE WITHSTAND DRY TESTS ON THE MAIN CIRCUIT.
    26 - 7.2 VOLTAGE WITHSTAND TESTS ON AUXILIARY AND CONTROL CIRCUITS
    26 - 7.3 MEASUREMENT OF THE RESISTANCE OF THE MAIN CIRCUIT
    26 - 7.101 MECHANICAL OPERATING TESTS.
    26 - 8. GUIDE TO THE SELECTION OF SWITCHING DEVICES
    26 - 8.1 GENERAL.
    27 - 8.2 SELECTION OF RATED VALUES FOR NORMAL SERVICE CONDITIONS.
    27 - 8.2.1 Selection of rated voltage.
    27 - 8.2.2 Insulation coordination.
    27 - 8.2.3 Selection of rated normal current.
    27 - 8.2.4 Local atmospheric and service conditions.
    27 - 8.2.5 Selection of rated short-time withstand current and of rated duration of short-circuit
    27 - 8.2.6 Selection of rated peak withstand current and for earthing switches of rated short-circuit making current
    27 - 9. INFORMATION TO BE GIVEN WITH ENQUIRIES, TENDERS AND ORDERS
    27 - 9.1 INFORMATION TO BE GIVEN WITH ENQUIRIES AND ORDERS
    28 - 9.2 INFORMATION TO BE GIVEN WITH TENDERS
    29 - 10. TRANSPORT, STORAGE, ERECTION AND MAINTENANCE
    29 - 11. QUALITY CONTROL DURING MANUFACTURE.
    30 - APPENDIX AA - PROCEDURE FOR ARRANGING PRE-ARCING CONDITION WHEN TESTING EARTHING SWITCHES FOR MAKING CAPACITY AT REDUCED VOLT
    31 - APPENDIX BB - PREFERRED NOMENCLATURE FOR TYPES OF AIR INSULATED DISCONNECTORS AND EARTHING SWITCHES AND USUAL RATED VOLTAGE R
    32 - APPENDIX CC - ITEMS SUBJECT TO AGREEMENT BETWEEN THE PURCHASER AND THE MANUFACTURER
    33 - ANNEX - SUMMARY OF TECHNICAL VARIATIONS BETWEEN THIS STANDARD AND IEC 129

    Abstract - (Show below) - (Hide below)

    Specifies requirements for disconnectors (isolators) and earthing switches designed for indoor and outdoor use at service frequencies up to and including 60 Hz in systems having rated voltages exceeding 1000 V. Applies also to the operating devices of these switches and to their auxiliary equipment. Includes service conditions, definitions, ratings, design and construction requirements, type and routine tests, guide to the selection of switching devices, information to be given with enquiries, tenders and orders, requirements for transport, storage, erection and maintenance, and a recommendation for quality control during manufacture.

    Scope - (Show below) - (Hide below)

    This standard applies to disconnectors (isolators) and earthing switches designed for use outdoors or indoors at service frequencies up to and including 60 Hz in systems having rated voltages exceeding 1000 V.NOTE: The IEC term 'disconnector' is used henceforth throughout this standard and replaces the term 'isolator' as used in the previous edition of this standard. This standard also applies to the operating devices of the disconnectors and earthing switches and to their auxiliary equipment.NOTES:1. The isolating properties assigned to disconnector-fuses and drop-out fuses should comply with the requirements of this standard. (See AS 1033.)2. Earthing switches forming an integral part of a high voltage switch or disconnector must comply with this standard. (See AS 1025.)3. Other parts of an installation, such as plug devices and movable circuit-breakers in metal-enclosed switchgear, may so be used as disconnectors, provided that they comply with this standard.

    General Product Information - (Show below) - (Hide below)

    Committee EL-007
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 62271.100-2005 High-voltage switchgear and controlgear High-voltage alternating current circuit-breakers (IEC 62271-100, Ed. 1.1 (2003) MOD)
    AS 2264-1995 A.C. insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 38 kV
    AS 2067-1984 Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV
    AS 2263-1995 Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
    AS/NZS 60265.1:2001 High-voltage switches Switches for rated voltages above 1 kV and less than 52 kV (IEC 60265-1:1998, MOD) (Reconfirmed 2016)
    AS 60470-2001 High-voltage alternating current contactors and contactor-based motor starters (Reconfirmed 2015)
    AS 4298-1995 Gas-insulated metal-enclosed switchgear for rated voltages 72.5 kV and above - Requirements for switching of bus-charging currents by disconnectors
    AS 2024-1991 High voltage a.c. switchgear and controlgear - Switch-fuse combinations
    AS 1243-1982 Voltage transformers for measurement and protection
    AS 1033.1-1990 High voltage fuses (for rated voltages exceeding 1000 V) Expulsion type (Reconfirmed 2018)
    AS 2086-1995 A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 72.5 kV
    AS 1025.2-1989 High-voltage a.c. switchgear and controlgear - Switches and switch-disconnectors - For rated voltages of 52 kV and above
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective