    Rotating electrical machines - General requirements - Noise limits

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  26-06-2021

    Language(s):  English

    Published date:  01-01-1998

    Publisher:  Standards Australia

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Specifies maximum A-weighted sound power levels for new machines from 1 kW (or kVA) to 5500 kW (or kVA) at no load. For certain three-phase induction motors, maximum power levels are specified both for no load and for rated load. This Standard is identical with and has been reproduced from IEC 60034-9:1997.

    Scope - (Show below) - (Hide below)

    This part of IEC 60034 specifies maximum A-weighted sound power levels for factory acceptance testing of rotating electrical machines in accordance with IEC 60034-1, having methods of cooling according to IEC 60034-6 and degrees of protection according to IEC 60034-5, and having the following characteristics:- standard design, either a.c. or d.c., without additional special electrical, mechanical, or acoustical modifications intended to reduce the noise level;- rated output from 1 kW (or kVA) up to and including 5 500 kW (or kVA);- speed not greater than 3 750 min-1.Excluded are a.c. motors supplied by convertors. For these conditions see IEC 60034-17 for guidance.NOTES1 This standard recognizes the economic reason for the availability of standard noise-level machines for use in non-critical areas or for use with supplementary means of noise attenuation.2 Where noise levels lower than those specified in tables 1 or 2 are required, these should be agreed between the manufacturer and the purchaser, as special electrical, mechanical, or acoustical design may involve addItional cost.The object of this standard is to determine maximum A-weighted sound power levels, in LWA decibels, dB, for airborne noise emitted by rotating electrical machines of standard design, as a function of power, speed and load, and to specify the method of measurement and the test conditions appropriate for the determination of the sound power level of the machines to provide a standardized evaluation of machine noise up to the maximum specified sound power levels. This standard does not provide correction for the existence of tonal characteristics.Sound pressure levels at a distance from the machine may be required in some applications, such as hearing protection programs. However, this standard is only concerned with the physical aspect of noise, to express limits in terms of sound power. In situ sound pressure calculations require knowledge of machine size, operating conditions and the environment in which the machine is to be installed. Information for such calculations taking into account environmental factors can be found, if needed, in classical textbooks on acoustics.

    General Product Information - (Show below) - (Hide below)

    Committee EL-009
    Document Type Standard
    Publisher Standards Australia
    Status Superseded
    Superseded By
    Supersedes
    Under Revision

    History - (Show below) - (Hide below)

    First published as AS 1359.51-1978.Second edition 1986.Revised and redesignated AS 1359.109-1998. First published as AS 1359.51-1978. Second edition 1986. Revised and redesignated AS 1359.109-1998.

    Standards Referenced By This Book - (Show below) - (Hide below)

    AS 1359.106-1996 Rotating electrical machines - General requirements - Methods of cooling (IC Code)
    AS 1359.20-1980 Rotating electrical machines - General requirements - Classification of types of enclosure
    AS 1217.6-1985 Acoustics - Determination of sound power levels of noise sources Precision methods for anechoic and hemi-anechoic rooms
    AS 1359.101-1997 Rotating electrical machines - General requirements - Rating and performance

    Standards Referencing This Book - (Show below) - (Hide below)

    AS 2941-2008 Fixed fire protection installations - Pumpset systems
    AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
    AS 61800.4-2007 Adjustable speed electrical power drive systems General requirements - Rating specifications for a.c. power drive systems above 1000 V a.c. and not exceeding 35 kV (Reconfirmed 2016)
    AS 4509.2-2002 Stand-alone power systems - System design guidelines
    AS 61800.1-2007 Adjustable speed electrical power drive systems General requirements - Rating specifications for low voltage adjustable speed d.c. power drive systems (Reconfirmed 2016)
    AS 61800.2-2004 Adjustable speed electrical power drive systems General requirements - Rating specifications for low voltage adjustable frequency a.c. power drive systems
    AS 1418.6-2004 Cranes, hoists and winches Guided storing and retrieving appliances (Reconfirmed 2018)
    AS/NZS 4509.2:2010 Stand-alone power systems System design (Reconfirmed 2017)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective