AS 1410-1987

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Sterilizers - Steam - Pre-vacuum

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

23-05-2024

Superseded by

AS 1410-2003

Published date

01-01-1987

€45.79
Excluding VAT

1 - AS 1410-1987 STERILIZERS - STEAM - PRE-VACUUM
4 - PREFACE
5 - CONTENTS
7 - SECTION 1. SCOPE AND GENERAL
7 - 1.1 SCOPE.
7 - 1.2 APPLICATION.
7 - 1.3 REFERENCED DOCUMENTS.
7 - 1.4 EXPRESSION OF PRESSURE VALUES
8 - SECTION 2. MATERIALS
8 - 2.1 GENERAL.
8 - 2.2 CHAMBER, JACKET, DOOR RING AND DOOR
8 - 2.3 MATERIALS FOR CONNECTIONS WELDED TO THE CHAMBER
8 - 2.4 MATERIALS FOR CONNECTIONS WELDED TO THE JACKET
8 - 2.5 PIPEWORK AND PIPEFITTINGS.
8 - 2.6 WELDING AND BRAZING.
8 - 2.7 FRAMEWORK.
8 - 2.8 EXTERNAL PANELS.
9 - SECTION 3. DESIGN
9 - 3.1 GENERAL.
9 - 3.2 CHAMBER AND JACKET.
9 - 3.2.1 Internal dimensions of the chamber.
9 - 3.2.2 Jacket.
9 - 3.2.3 Design pressure.
9 - 3.2.4 Cladding.
9 - 3.2.5 Ends.
9 - 3.2.6 Provision for instruments and test equipment
9 - 3.3 WORKING HEIGHT.
9 - 3.4 MOUNTING.
9 - 3.5 DOORS.
9 - 3.5.1 Provision of doors.
9 - 3.5.2 Door operation.
9 - 3.5.3 Door rings.
9 - 3.5.4 Door gasket.
9 - 3.6 CONTROLS.
9 - 3.6.1 Steam pressure control.
10 - 3.6.2 Automatic process control.
10 - 3.6.3 Air leak test control.
10 - 3.6.4 Additional controls for sterilizers with doors at both ends
10 - 3.7 THERMAL INSULATION.
10 - 3.8 CONNECTIONS AND FITTINGS.
10 - 3.8.1 Steam inlet to chamber.
10 - 3.8.2 Condensate and air discharge.
11 - 3.8.3 Pipework and pipe fittings.
11 - 3.8.4 Drains.
11 - 3.8.5 Temperature sensors.
11 - 3.8.6 Air detector test valve.
11 - 3.8.7 Safety valves.
11 - 3.8.8 Valves.
11 - 3.8.9 Air filters.
11 - 3.8.10 Panel-mounted equipment.
12 - 3.8.11 Process recorder.
12 - 3.8.12 Entry for leads.
12 - 3.9 LOADING EQUIPMENT.
12 - 3.10 AIR REMOVAL.
12 - 3.11 WATER SUPPLY.
12 - 3.12 VIBRATION ISOLATION.
12 - 3.13 FRAME.
12 - 3.14 EXTERNAL PANELS.
12 - 3.15 VENTILATION.
13 - SECTION 4. CONSTRUCTION
13 - 4.1 GENERAL.
13 - 4.2 WELDING.
13 - 4.3 JACKET.
13 - 4.4 FINISH.
13 - 4.4.1 Internal.
13 - 4.4.2 External.
13 - 4.4.3 Doors and door rings.
13 - 4.4.4 Pipework and pipe fittings.
13 - 4.5 FRAME.
13 - 4.6 EXTERNAL PANELS.
13 - SECTION 5. ELECTRICALLY CONTROLLED EQUIPMENT
13 - 5.1 GENERAL.
13 - 5.2 CONTROLS.
13 - 5.3 TIMERS.
13 - 5.4 CYCLE INDICATOR.
14 - SECTION 6. MARKING DATA AND INFORMATION
14 - 6.1 MARKING.
14 - 6.1.1 Sterilizer.
14 - 6.1.2 Controlling and indicating equipment.
14 - 6.2 TECHNICAL MANUAL.
15 - SECTION 7. TESTING
15 - 7.1 TESTS.
15 - 7.2 METHODS OF TEST.
15 - 7.3 TEST REQUIREMENTS.
16 - APPENDIX A - INFORMATION TO BE SUPPLIED WITH ENQUIRIES AND ORDERS
16 - A1 GENERAL.
16 - A2 MATTERS TO BE RESOLVED.
16 - A3 INFORMATION TO BE SUPPLIED BY THE PURCHASER.
17 - APPENDIX B - INSTALLATION
17 - B1 HAZARDOUS AREAS.
17 - B2 METHOD OF INTRODUCING THERMOCOUPLES INTO STERILIZER CHAMBER
20 - APPENDIX C - METHODS OF TEST FOR PERFORMANCE AND FUNCTIONING
20 - C1 SCOPE.
20 - C2 THE BOWIE/DICK TAPE TEST FOR POROUS LOAD STERILIZERS.*
22 - C3 LEAK RATE TEST FOR POROUS LOAD STERILIZERS.
23 - C4 AIR DETECTOR TESTS.
23 - C4.1 Air detector tests for porous load sterilizers.
24 - C4.2 Types of tests.
24 - C4.3 Particular features of the function test.
24 - C4.4 Particular features of the performance test.
25 - C5 COMPARISON BETWEEN FUNCTION TEST AND PERFORMANCE TEST
25 - C6 TEST REQUIREMENTS.
28 - APPENDIX D - QUALITY OF WATER
28 - D1 AVAILABILITY OF ADEQUATE WATER QUALITY.
28 - D2 TREATED WATER.

Specifies requirements for fully automatic jacketed pre-vacuum steam sterilizers, which operate at a sterilizing temperature of 134 degrees Celsius and are intended for use in hospitals and other non-industrial applications for the sterilization of porous loads, and instruments and utensils wrapped in porous material. The sterilizers are not intended for the sterilization of fluids, or for installation in areas associated with the use of flammable anaesthetics. Guidance on information to be supplied with enquiries and orders, guidance on installation, methods of test, and information on quality of water are given in appendices.

Committee
ME-003
DocumentType
Standard
ISBN
0 7262 4459 7
Pages
22
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This standard specifies requirements for fully automatic jacketed pre-vacuum steam sterilizers, which operate at a sterilizing temperature of 134C and are intended for use in hospitals and other non-industrial applications for the sterilization of porous loads, and instruments and utensils wrapped in porous material.The sterilizers are not intended for sterilization of fluids, or installation in areas associated with the use of flammable anaesthetics.NOTE: Guidance on information to be supplied with enquiries and orders, guidance on installation, methods of test, and information on quality of water are given in Appendices A to D respectively.

Under Revision see DR 01307

AS/NZS 2243.3:2002 Safety in laboratories Microbiological aspects and containment facilities
AS/NZS 1200:2000 Pressure equipment
AS 4037-1992 Boilers and pressure vessels - Examination and testing
AS/NZS 4815:2001 Office-based health care facilities not involved in complex patient procedures and processes - Cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of the associated environment
AS 4187-1994 Code of practice for cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of associated environments in health care facilities
AS/NZS 1200:1994 Pressure equipment
AS 4187-1998 Cleaning, disinfecting and sterilizing reusable medical and surgical instruments and equipment, and maintenance of associated environments in health care facilities
AS/NZS 2982.1:1997 Laboratory design and construction General requirements
AS 1079.3-1994 Packaging of items (sterile) for patient care Paper bags - For single use in health care facilities
AS 1079.1-1993 Packaging of items (sterile) for patient care - Selection of packaging materials for goods undergoing sterilization
AS/NZS 2243.3:1995 Safety in laboratories Microbiology

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.