AS 1600.1-1988

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Medical equipment - Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - General requirements

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-04-2018

Superseded by

AS 1600.1-2004

Language(s)

English

Published date

01-01-1988

€15.02
Excluding VAT

1 - AS 1600.1-1988 MEDICAL EQUIPMENT - CONICAL FITTINGS WITH A SIX PERCENT (LUER) TAPER FOR SYRINGES, NEEDLES AND CERTAIN OTHER M
4 - PREFACE
5 - CONTENTS
6 - 0 Introduction
6 - 1 Scope and field of application
6 - 2 References
6 - 3 Dimensions
8 - 4 Requirements
8 - 4.1 Gauging
8 - 4.2 Liquid leakage
8 - 4.3 Air leakage
8 - 4.4 Separation force
8 - 4.5 Stress cracking
9 - 5 Test methods
9 - 5.1 Gauging test
9 - 5.2 Test method for liquid leakage from the conical fitting assembly under pressure
9 - 5.3 Test method for air leakage into the conical fitting assembly during aspiration
9 - 5.3.1 Male fittings
9 - 5.3.2 Female fittings
9 - 5.4 Test method for separation force of conical fitting assembly
9 - 5.5 Method of testing for stress cracking
12 - Annex - Liquid leakage
12 - A.1 Specification
12 - A.2 Test method for leakage rate

Specifies requirements for conical fittings with a 6 percent (Luer) taper for use with hypodermic syringes and needles with certain other apparatus for medical use such as transfusion and infusion sets. It covers conical fittings made of rigid and semi-rigid materials and includes test methods for gauging and performance. The Standard is identical with and has been reproduced from ISO 594-1:1986.

Committee
HE-009
DocumentType
Standard
ISBN
0 7262 5146 1
Pages
7
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This part of ISO 594 specifies requirements for conical fittings with a 6% (Luer) taper for use with hypodermic syringes and needles and with certain other apparatus for medical use such as transfusion and infusion sets.It covers conical fittings made of rigid and of semi-rigid materials and includes test methods for gauging and performance. It excludes provision for more flexible or elastomeric materials.Figure 1 illustrates typical male 6% (Luer) conical fitting ("male fitting") and female 6% (Luer) conical fitting ("female fitting").

Standards Relationship
ISO 594-1:1986 Identical

Under Revision see DR 03226

AS 1094-1993 Medical equipment - Single-use syringes (sterile) for general medical use
AS 1077-1992 Single-use syringes (sterile) for the injection of 100 units per millilitre insulin (U-100)
AS/NZS 2696:1996 Medical devices - Polymer urethral catheters for general medical use

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.