AS 1735.12-1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lifts, escalators and moving walks Facilities for persons with disabilities
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
15-07-2024
05-05-1999
SECTION 1 - SCOPE AND GENERAL 1.1 SCOPE 1.1 APPLICATION 1.2 REFERENCED DOCUMENTS 1.3 DEFINITIONSSECTION 2 - LIFT CAR SIZESECTION 3 - CAR FLOORS 3.1 SURFACES 3.2 ACCESS TO SAFETY GEARSECTION 4 - DOORS 4.1 TYPES 4.2 PASSENGER-PROTECTION SYSTEMS 4.3 DOOR OPEN DWELL TIMESECTION 5 - CAR WALLS AND FITTINGS 5.1 SURFACES ADJACENT TO CONTROL BUTTONS 5.2 PROTRUDING EDGES 5.3 HANDRAILS 5.4 SEATSSECTION 6 - LEVELLING OF LIFT CARSSECTION 7 - CONTROL BUTTONS 7.1 PROVISION AT LANDINGS 7.2 PROVISION IN LIFT CARS 7.3 LOCATION 7.4 DESIGNSECTION 8 - INFORMATION 8.1 AUTOMATIC AUDIBLE INFORMATION 8.2 VISIBLE INFORMATION 8.3 TACTILE INFORMATION 8.4 SHAPE OF CHARACTERS 8.5 INDICATION OF TRAVEL DIRECTION 8.6 PROVISION IN LIFT CARSSECTION 9 - COMMUNICATION SYSTEMS 9.1 PROVISION 9.2 ACKNOWLEDGMENT OF COMMUNICATION 9.3 LIFT IDENTIFICATION FOR COMMUNICATION SYSTEM 9.4 PERMANENTLY ATTENDED LOCATION 9.5 LIFT CARSECTION 10 - LIGHTING 10.1 COMPLIANCE WITH AS/NZS 1680.0 10.2 GENERAL LIGHTING WITHIN LIFT CARS 10.3 LIGHTING OF LIFT CAR CONTROLSAPPENDIX A TYPICAL ARRANGEMENT OF A LIFT ENTRANCEINDEX
Sets out requirements for passenger lifts which are specifically designed to assist persons with disabilities. Applies only to lifts for which a building authority having jurisdiction stipulates the provision of facilities for persons with disabilities; however, it does not apply to lifts in a private residence.
Committee |
ME-004
|
DocumentType |
Standard
|
ISBN |
0 7337 2665 8
|
Pages |
19
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out requirements for facilities in passenger lifts that are specifically designed to assist persons with disabilities. It is complementary to AS 1735.1, AS 1735.2 and AS 1735.3.Where any conflict arises between Parts of AS 1735, the provisions of this Part shall take precedence.
First published as AS 1735.12-1986.
Second edition 1994.
Third edition 1999.
AS 1735.3-1995 | Lifts, escalators and moving walks Passenger and goods lifts - Electrohydraulic |
AS 1735.2-1997 | Lifts, escalators and moving walks Passenger and goods lifts - Electric |
AS 1735.3-2002 | Lifts, escalators and moving walks Passenger and goods lifts - Electrohydraulic |
AS 1735.2-2001 | Lifts, escalators and moving walks Passenger and goods lifts - Electric |
AS 1259.1-1990 | Acoustics - Sound level meters Non-integrating |
AS/NZS 1680.0:1998 | Interior lighting Safe movement |
AS 1735.1-1999 | Lifts, escalators and moving walks - General requirements |
AS 2659.1-1988 | Guide to the use of sound measuring equipment - Portable sound level meters |
AS 1735.1-2003 | Lifts, escalators and moving walks General requirements |
AS 2118.1:2017 | Automatic fire sprinkler systems General systems |
AS 1735.17-1995 | Lifts, escalators and moving walks Lifts for people with limited mobility - Restricted use - Water-drive |
AS/NZS 2982:2010 | Laboratory design and construction |
AS/NZS 1170.1:2002 | Structural design actions Permanent, imposed and other actions |
AS/NZS 4024.1:2006 Series | Safety of machinery Safety of machinery series |
AS 4024.1202-2006 | Safety of machinery General principles - Technical principles |
AS/NZS 1680.2.1:2008 | Interior and workplace lighting Specific applications - Circulation spaces and other general areas |
AS/NZS 1428.4:2002 | Design for access and mobility Tactile indicators |
AS 1418.8-2008 | Cranes, hoists and winches Special purpose appliances (Reconfirmed 2018) |
AS 1735.2-2001 | Lifts, escalators and moving walks Passenger and goods lifts - Electric |
AS 1735.15-2002 | Lifts, escalators, and moving walks Low-rise passenger lifts - Non-automatically controlled |
AS 1428.2-1992 | Design for access and mobility Enhanced and additional requirements - Buildings and facilities (Reconfirmed 2015) |
AS 2359.2-2013 | Powered industrial trucks Operations |
AS 1428.1-2001 | Design for access and mobility General requirements for access - New building work |
AS 1735.16-1993 | Lifts, escalators and moving walks Lifts for persons with limited mobility - Restricted use - Automatically controlled |
AS 1428.5-2010 | Design for access and mobility Communication for people who are deaf or hearing impaired (Reconfirmed 2016) |
AS 1428.1-2009 | Design for access and mobility General requirements for access - New building work |
AS 2118.1-2006 | Automatic fire sprinkler systems General systems |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 2293.1:2018 | Emergency lighting and exit signs for buildings System design, installation and operation |
AS 1668.2-2012 | The use of ventilation and airconditioning in buildings Mechanical ventilation in buildings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.