• Shopping Cart
    There are no items in your cart

AS 2050-1989

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fixing of roofing tiles

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

24-05-2024

Superseded by

AS 2050-1995

Language(s)

English

Published date

01-01-1989

€32.89
Excluding VAT

1 - AS 2050-1989 FIXING OF ROOFING TILES
4 - PREFACE
5 - CONTENTS
6 - SECTION 1. SCOPE AND GENERAL
6 - 1.1 SCOPE.
6 - 1.2 REFERENCED DOCUMENTS.
6 - 1.3 DEFINITIONS.
6 - 1.3.1 Roof tile
6 - 1.3.2 Accessory
6 - 1.3.3 High wind areas
6 - 1.3.4 Fixing materials
6 - 1.3.5 Edge of roof
6 - 1.3.6 Required
6 - 1.3.7 Weatherproof
6 - 1.4 PERFORMANCE REQUIREMENTS FOR THE COMPLETED ROOF.
6 - 1.4.1 Loading.
6 - 1.4.2 Weather resistance.
7 - SECTION 2. MATERIALS
7 - 2.1 SARKING.
7 - 2.1.1 Pliable roof sarking.
7 - 2.1.2 Reflective foil laminate.
7 - 2.1.3 Rigid or semi-rigid materials.
7 - 2.2 TILING BATTENS.
7 - 2.2.1 Timber battens.
7 - 2.2.2 Steel battens.
7 - 2.3 MORTAR.
7 - 2.4 FIXING SYSTEMS.
8 - SECTION 3. FIXING
8 - 3.1 SARKING.
8 - 3.1.1 General.
8 - 3.1.2 Damage.
8 - 3.1.3 Anti-ponding facilities.
8 - 3.1.4 Requirements for roofs without general sarking
8 - 3.2 BATTENS AND RAFTERS.
8 - 3.2.1 General.
8 - 3.2.2 Batten alignment.
8 - 3.2.3 Batten spacing.
8 - 3.2.4 Batten fixing.
8 - 3.2.5 Batten joints.
8 - 3.3 TILES AND ACCESSORIES.
8 - 3.3.1 General.
8 - 3.3.2 Sarked roofs.
8 - 3.3.3 Set out.
8 - 3.3.4 Gable tiles.
8 - 3.3.5 Eaves tiles.
8 - 3.3.6 Hips.
8 - 3.3.7 Ridging.
8 - 3.3.8 Barge tiles.
8 - 3.4 BEDDING AND POINTING.
9 - 3.5 BIRDPROOFING AT VALLEYS.
9 - 3.6 TILING OVER FIREWAlLS.
9 - 3.7 WORKMANSHIP.
10 - APPENDIX A - PRECAUTIONS AGAINST WIND EFFECTS
10 - A1 GENERAL.
10 - A2 HIGH WIND AREAS.
10 - A3 WIND EFFECTS.
10 - A4 CONSTRUCTIONAL SAFEGUARDS IN HIGH WIND AREAS.
10 - A4.1 Fixing of tiles to battens.
10 - A4.2 Fixing of battens to rafters.
10 - A4.3 Use of sarking.
11 - APPENDIX B - INFORMATION AND OTHER INPUT NOT NORMALLY PROVIDED BY THE ROOF TILER
12 - APPENDIX C - DYNAMIC WEATHER RESISTANCE TEST
12 - C1 SCOPE.
12 - C2 PRINCIPLE.
12 - C3 APPARATUS.
12 - C4 TEST SPECIMEN.
12 - C5 CONTROL SPECIMEN.
12 - C6 PROCEDURE.
13 - C7 REPORT.

Specifies fixing requirements for concrete and terracotta roofing tiles. Requirements for sarking, batten fixing tolerances and mechanical fixing of tiles and accessories for various wind velocities are included, together with an overall requirement that the complete roof be weatherproof in terms of a dynamic weather resistance test which is included in an appendix.

Committee
BD-008
DocumentType
Standard
ISBN
0 7262 5949 7
Pages
8
ProductNote
See also AS 2050-1995
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard sets out requirements for the placement and fixing of concrete and terra cotta roofing tiles of the types specified in AS 1757 and AS 2049. The fixing methods described in this Standard apply only to roofs of buildings which are intended for domestic, commercial or light industrial purposes.This Standard applies only to roofs with a pitch of 15 or greater.NOTES:1. This Standard does not restrict the use of other fixing and fastening methods or materials where it can be shown that they are not inferior in performance to the performance achieved by the materials and methods described herein.2. Where it is intended to fix tiles to roofs with a pitch of less than 15, the tile manufacturer's advice should be sought.3. The type of roof construction described in this Standard may not be adequate to resist wind forces in cases where the height of the eaves is more than 15 m above the mean surrounding ground level. In such cases, or in areas where cyclones or high winds are known to occur, the fixing and fastening methods and sarking recommendations given in Appendix A are recommended.4. Appendix B provides information on the data normally provided by the specifier and the tile manufacturer, and on the work normally carried out as part of the tiling operation.

First published in part as AS CA5-1933.
AS CA6 first published 1933.
Second edition 1948.
Reprinted and redated AS CA6-1949.
Second edition AS CA5-1950.
Int 311 first published 1951.
Third edition AS CA5-1963.
Int 311-1951 revised and redesignated AS CA46-1967.
AS CA5-1963 revised and redesignated AS 2050-1977.
AS CA6-1949 revised and redesignated AS 1760-1975.
AS CA46-1967 revised and redesignated AS 1758-1975.
AS 1758-1975, AS 1760-1975 and AS 2050-1977 revised, amalgamated and designated AS 2050-1989.

AS 2049-1992 Roof tiles

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.