AS 2192-2002

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Sterilizers - Steam - Downward-displacement

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-2002

Withdrawn date

30-06-2017

€91.52
Excluding VAT
Summarise this standard

Specifies requirements for horizontal downward-displacement steam sterilizers (including jacketed types and non-jacketed types) that are intended for use in hospitals and other non-industrial applications. Guidance on information that should be supplied with enquiries and orders and information on quality of water and steam supplies is given in appendices.

Committee
ME-003
DocumentType
Standard
ISBN
0 7337 4662 4
Pages
46
ProductNote
Withdrawn 30-01-2017.
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This Standard specifies requirements for horizontal downward-displacement steam sterilizers (including jacketed types and non-jacketed types) that are intended for use in hospitals and other non-industrial applications.NOTES: 1 Downward-displacement-type steam sterilizers should not be used to sterilize any instrument or equipment that is lumened or blind lumened, as specified in AS 4187 (Clause 4.2.2 in the 2002 edition).2 Steam sterilizers require an independently generated saturated steam supply that has a dryness value of not less than 0.97 and an adequate steam quality. Information on steam quality is provided by HTM 2031.3 Steam sterilizers should not be installed in any location where flammable anaesthetics or volatile liquids may be used, unless the location and the sterilizer comply with the relevant requirements of AS 1169, AS 2380.2 and AS 2380.7.4 Guidance on information that should be supplied with enquiries and orders is given in Appendix A.5 Information on quality of water is given in Appendix B.6 Information on steam supplies is given in Appendix C.7 Standards for machines that wash, sterilize or dry medical equipment in health care facilities are listed in Appendix D.

First published in part as AS T54-1971.
AS T55 first published 1971.
AS T54-1971 and AS T55-1971 revised, amalgamated and redesignated as AS 2198-1978.
Second edition 1991.
Third edition 2002.

⚠

This standard has been withdrawn and is no longer current. No replacement edition is available.