• There are no items in your cart

AS 2242.1.1-1979

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Instrumental methods for the analysis of milk and milk products Determination of fat in whole milk - Turbidimetric methods

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Language(s)

English

Published date

01-01-1979

1 - AS 2242.1.1-1979 INSTRUMENTAL METHODS FOR ANALYSIS OF MILK AND MILK PRODUCTS - DETERMINATION OF FAT IN WHOLE MILK - TURBIDIM
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - METHOD
7 - 1 SCOPE.
7 - 2 APPLICATION.
7 - 3 PRINCIPLE.
7 - 4 MATERIALS AND REAGENTS.
7 - 4.1 Materials.
7 - 4.2 Reagents.
7 - 5 APPARATUS.
7 - 6 PREPARATION OF SAMPLES FOR TESTING.
7 - 6.1 Condition.
7 - 6.2 Storage.
7 - 6.3 Provisions for Mixing.
7 - 6.4 Preparation.
8 - 7 CALIBRATION OF THE INSTRUMENT.
8 - 7.1 Basic Procedure.
9 - 7.2 Calibration Conformance Check.
9 - 7.3 Daily Check Test.
10 - 8 PROCEDURE FOR THE OPERATION OF THE INSTRUMENT.
10 - 9 REPORT.
10 - 10 REPEATABILITY.
11 - APPENDIX A - DETERMINATION OF THE FAT IN WHOLE MILK USING THE FOSS 'MILKO' TESTER MARK III
11 - A1 SCOPE.
11 - A2 APPLICATION.
11 - A3 PRINCIPLE.
11 - A4 MATERIALS AND REAGENTS.
11 - A4.1 Materials.
11 - A4.2 Reagents.
12 - A5 APPARATUS.
12 - A6 PREPARATION OF SAMPLES.
12 - A7 CALIBRATION OF THE INSTRUMENT.
12 - A8 PROCEDURE FOR OPERATION OF THE INSTRUMENT
12 - A8.1 Instrument Parameters and Components.
13 - A8.2 Routine Daily Inspection.
13 - A8.3 Electrical Checks- Zero and Shift Value.
15 - A8.4 Calibration.
15 - A8.5 Procedure for Making a Measurement
15 - A9 REPORT.
15 - A10 REPEATABILITY.
15 - ANNEX 1 TO APPENDIX A - ADJUSTMENTS TO OBTAIN MAXIMUM ACCURACY
15 - 1 GENERAL.
16 - 2 CHECK OF CALIBRATION.
18 - 3 READJUSTMENT OF THE INSTRUMENT.
20 - ANNEX 2 TO APPENDIX A - CALCULATIONS RELATING TO INSTRUMENT CALIBRATION
20 - 1 CALCULATION OF NUMBER OF DETERMINATIONS FOR EQUIVALENT PRECISION.
22 - 2 CALCULATION OF THE PERMITTED DIFFERENCE BETWEEN THE RESULTS OBTAINED BY THE ‘MILKO’ TESTER MARK III AND THE SELECTED REFERE
23 - 3 CALCULATION OF THE CALIBRATION STATISTIC

Describes a general method for the instrumental analysis of fat in whole milk using a turbidimetric technique and which stipulates measures for the preparation of samples for testing instrument calibration and the procedure for operation. An appendix describes the detailed determination using the Foss 'Milko' Tester Mark III and provision exists for the addition of further appendices as other instruments gain acceptance.

Committee
FT-024
DocumentType
Standard
ISBN
0 7262 1631 3
Pages
19
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This standard describes instrumental methods based on a turbidimetric principle for determining the fat in whole milk.NOTE: A particular method using a specific instrument, i.e. Foss 'Milko' Tester Mark III, is given in Appendix A. Provision exists for the progressive addition of further similar appendices relating to other instruments.

Reconfirmed 1993

AS 2300.2.1-1996 Methods of chemical and physical testing for the dairying industry Liquid milks - Method for determining the efficiency of homogenization of milk (Reconfirmed 2016)

View more information
€32.89
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.