AS 2326.1-1991
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
On-load tap-changers - Requirements
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
01-01-1991
Specifies design requirements and tests for on-load tap-changers and their motor-drive mechanisms immersed in transformer oil. It applies also to gas-insulated tap-changers, but excludes tap-changers for transformers for railway rolling stock. This Standard is technically identical with IEC 214:1989, On-load tap-changers.
Committee |
EL-008
|
DocumentType |
Standard
|
ISBN |
0 7262 6922 0
|
Pages |
36
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This standard applies to on-load tap-changers* for power transformers and their motor-drive mechanisms. It relates mainly to tap-changers immersed in transformer oil according to IEC Publication 296, but may also be used for gas-insulated tap-changers in so far as conditions are applicable.Note.- For the purpose of this standard, a synthetic insulating liquid is regarded as an oil. A synthetic insulating liquid can be used for a tap-changer only if it is compatible with the tap-changer design.Tap-changers for transformers for railway rolling stock are excluded from this standard.In selecting a tap-changer for a particular application, reference should be made to IEC Publication 542.
Standards | Relationship |
IEC 60214:1989 | Identical |
First published as AS C378-1967.
Revised and redesignated AS 2326.1-1980.
Second edition 1991.
AS 2374.1-1997 | Power transformers General |
AS 1931.1-1996 | High-voltage test techniques - General definitions and test requirements |
AS 1018-1985 | Partial discharge measurements |
AS 2326.2-1991 | On-load tap-changers - Application guide |
AS 1265-1990 | Bushings for alternating voltages above 1000 V |
AS 1767-1975 | Insulating oil for transformers and switchgear |
AS 2374.3.0-1982 | Power transformers Insulation levels and dielectric tests - General requirements |
AS 1078-1984 | Guide to loading of oil-immersed transformers |
AS 2326.2-1991 | On-load tap-changers - Application guide |
AS 2374.3.0-1982 | Power transformers Insulation levels and dielectric tests - General requirements |