AS 2360.6.1-1993
Current
The latest, up-to-date edition.
Measurement of fluid flow in closed conduits Volumetric methods - By mass
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
20-12-1993
Specifies a method for the determination of fluid flow, in a conduit running full, by measurement of the mass of water delivered into a weighing tank in a known time interval. The application is generally for fixed laboratory installations with flow rates of less than 1500kL/s. It is identical with and has been reproduced from ISO4185:1980.
Committee |
CE/24
|
DevelopmentNote |
Standard given Pending Revision status.
|
DocumentType |
Standard
|
ISBN |
0 7262 8497 1
|
Pages |
21
|
ProductNote |
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
|
PublisherName |
Standards Australia
|
Status |
Current
|
This International Standard specifies a method of liquid flow-rate measurement in closed conduits by measuring the mass of liquid delivered into a weighing tank in a known time interval. It deals in particular with the measuring apparatus, the procedure, the method for calculating the flow-rate and the uncertainties associated with the measurement.The method described may be applied to any liquid provided that its vapour pressure is such that any escape of liquid from the weighing tank by vaporization is not sufficient to affect the required measurement accuracy. Closed weighing tanks and their application to the flow measurement of liquids of high vapour pressure are not considered in this International Standard.This International Standard does not cover the cases of corrosive or toxic liquids.Theoretically, there is no limit to the application of this method which is used generally in fixed laboratory installations only. However, for economic reasons, usual hydraulic laboratories using this method can produce flow-rates of 1.5 m 3/s or less.Owing to its high potential accuracy, this method is often used as a primary method for calibration of other methods or devices for mass flow-rate measurement or volume flow-rate measurement provided that the density of the liquid is known accurately.It must be ensured that the pipeline is running full with no air or vapour pockets present in the measuring section.
Standards | Relationship |
ISO 4185:1980 | Identical |
First published as AS 2360.6.1-1993.
Reissued incorporating Amendment No 1 (June 2023).
AS 2360.0-1993 | Measurement of fluid flow in closed conduits Vocabulary and symbols (Reconfirmed 2019) |
AS 3778.2.4-2007 | Measurement of water flow in open channels General - Estimation of uncertainty of a flow rate measurement (Reconfirmed 2022) |
AS 3778.2.4-1990 | Measurement of water flow in open channels General - Estimation of uncertainty of a flow-rate measurement |
AS 5102.1:2019 | Performance of household electrical appliances - Swimming pool pump-units Measurement of energy consumption and performance |
AS 2360.6.2-1993 | Measurement of fluid flow in closed conduits Volumetric methods - By volume (Reconfirmed 2022) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.