• Shopping Cart
    There are no items in your cart

AS 2464.3-1983

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Methods of testing thermal insulation Thermal resistance of low-density loose-fill insulation

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

03-03-2024

Superseded by

AS/NZS 4859.1:2002

Language(s)

English

Published date

04-07-1983

€24.96
Excluding VAT

1 - AS 2464.3-1983 METHODS OF TESTING THERMAL INSULATION - THERMAL RESISTANCE OF LOW-DENSITY LOOSE-FILL INSULATION
1 - 1 SCOPE.
1 - 2 APPLICATION.
1 - 3 REFERENCED DOCUMENTS.
1 - 4 DEFINITIONS.
1 - 5 PRINCIPLE AND GENERAL CONSIDERATIONS.
1 - 5.1 Calculations on Installed Condition.
1 - 5.2 Thermal Conductance.
1 - 5.3 Thermal Resistance.
1 - 5.4 Homogeneity.
1 - 5.5 Normal Use.
2 - 5.6 Guarded Hotplate.
2 - 5.7 Heat Flow Meter.
2 - 5.8 Density Determination.
2 - 6 APPARATUS.
2 - 6.1 Configuration.
2 - 6.2 Size.
2 - 6.3 Heat Meter Placement and Configuration.
2 - 6.4 General Arrangement of Apparatus.
3 - 6.5 Temperature of Operation.
3 - 6.6 Heating and Cooling System Controls.
3 - 7 SAMPLE PREPARATION.
3 - 7.1. Selection.
3 - 7.2 Containment Frame.
3 - 7.3 Calculation of Mass.
3 - 7.4 Selection of Test Specimen.
4 - 7.5 Conditioning of Test Specimen.
4 - 7.6 Preparation of Test Specimen.
4 - 8 PROCEDURE.
4 - 9 CALCULATIONS.
4 - 9.1 Thermal Conductance.
5 - 9.2 Thermal Resistance.
5 - 10 REPORT.

AS 2464.3-1983 sets out a method of test to determine the thermal resistance of low-density fibrous loose-fill thermal insulation for use in the temperature range −18°C to 55°C.

Committee
BD-058
DocumentType
Standard
ISBN
0 7262 3015 4
Pages
5
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This standard sets out a method of test to determine the thermal resistance of low-density fibrous loose-fill thermal insulation for use in the temperature range -18C to 55C. It is primarily intended for use with pneumatically applied thermal insulation, but it may also be used with poured-in-place thermal insulation.

Under Revision See DR 02026 CP

AS 2464.2-1981 Methods of testing thermal insulation - Bulk density of blown fibrous loose-fill thermal insulation
AS 2464.5-1985 Methods of testing thermal insulation Steady-state thermal transmission properties by means of the heat flow meter
AS 2464.6-1983 Methods of testing thermal insulation - Steady-state thermal transmission properties by means of the guarded hot plate
AS 2352-1980 Glossary of terms for thermal insulation of buildings

AS 2461-1981 Mineral wool thermal insulation - Loose fill
AS 2463-1981 Sea grass bulk thermal insulation
AS 2462-1981 Cellulosic fibre thermal insulation