• Shopping Cart
    There are no items in your cart

AS 2627.1-1993

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Thermal insulation of dwellings Thermal insulation of roof/ceilings and walls in dwellings

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Published date

13-09-1993

€111.46
Excluding VAT

1 - AS 2627.1-1993 THERMAL INSULATION OF ROOF/CEILINGS AND WALLS IN DWELLINGS
4 - PREFACE
6 - CONTENTS
7 - FOREWORD
9 - SECTION 1 SCOPE AND GENERAL
9 - 1.1 SCOPE
9 - 1.2 APPLICATION
9 - 1.3 REFERENCED DOCUMENTS
9 - 1.4 DEFINITIONS
9 - 1.5 THERMAL PERFORMANCE
9 - 1.6 GENERAL
11 - SECTION 2 RECOMMENDED THERMAL RESISTANCE REQUIREMENTS
11 - 2.1 SCOPE OF SECTION
11 - 2.2 APPLICATION
13 - 2.3 RECOMMENDED ADDITIONAL THERMAL RESISTANCE REQUIREMENTS
13 - 2.4 RECOMMENDED ADDITIONAL THERMAL RESISTANCE REQUIREMENTS FOR WALLS
54 - SECTION 3 METHOD OF CALCULATION OF THERMAL RESISTANCE
54 - 3.1 SCOPE OF SECTION
54 - 3.2 PARAMETERS
54 - 3.3 METHOD OF CALCULATION
57 - 3.4 HEATING OR COOLING NUMBER
57 - 3.5 PRESENT WORTH FACTOR
58 - 3.6 COST OF ENERGY
58 - 3.7 SEASONAL EFFICIENCY OF HEATING OR COOLING EQUIPMENT
59 - 3.8 COST OF INSULATION
59 - 3.9 THERMAL RESISTANCE OF EXISTING ROOF/CEILING OR WALL
60 - 3.10 EXAMPLE CALCULATION FOR ROOF/CEILING
61 - 3.11 EXAMPLE CALCULATION FOR WALL
63 - APPENDIX A - BACKGROUND TO THIS STANDARD
63 - A1 SCOPE
63 - A2 GENERAL
64 - A3 HEATING AND COOLING NUMBER
65 - A4 PRESENT WORTH FACTOR
66 - A5 HEATER AND COOLER EFFICIENCY AND COST OF ENERGY
67 - A6 COEFFICIENT FOR COST OF INSULATION
68 - A7 THERMAL RESISTANCE OF UNINSULATED ROOF/CEILING
68 - A8 AVERAGE THERMAL RESISTANCES OF UNINSULATED WALLS
69 - APPENDIX B - DERIVATION OF EXPRESSION FOR ADDITIONAL THERMAL RESISTANCE IN THE ROOF/CEILING OVER A HEATED OR COOLED SPACE
69 - B1 SCOPE
69 - B2 NOTATION
69 - B3 DERIVATION
75 - APPENDIX C - DERIVATION OF EXPRESSIONS FOR CALCULATING THE SAVINGS ATTRIBUTABLE TO ADDITIONAL THERMAL RESISTANCE IN WALLS
75 - C1 SCOPE
75 - C2 NOTATION
76 - C3 DERIVATION
78 - APPENDIX D - THERMAL RESISTANCE OF ROOF/CEILING STRUCTURES
87 - APPENDIX E - THERMAL RESISTANCE OF BUILDING MATERIALS, AIR FILMS, AIRSPACES AND ROOF SPACES
91 - APPENDIX F - EXPLANATION OF HEATING AND COOLING NUMBER CONCEPT
91 - F1 HEATING NUMBER
93 - F2 COOLING NUMBERS
95 - APPENDIX G - LIST OF HEATING NUMBERS (BASE TEMPERATURES 15°C) AND COOLING NUMBERS (BASE TEMPERATURE VARIES WITH CLIMATE)

Specifies requirements and recommendations relating to the additional thermal resistance for the roof/ceiling space over the heated or cooled areas and walls of those areas of dwellings that are heated or cooled for substantial periods of the year.

Committee
EN-003
DocumentType
Standard
ISBN
0 7262 8417 3
Pages
110
ProductNote
See also HB 63-1994
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

This Standard sets out requirements and recommendations relating to the additional thermal resistance for the roof/ceiling space over the heated or cooled areas and walls of those areas of dwellings that are heated or cooled for substantial periods of the year.

First published as AS 2627.1-1983.
Second edition 1993.

AS 2900.4-1986 Quantities, units, and symbols - Quantities and units of heat
AS 2900.4-2002 Quantities and units - Heat
AS 2352-1980 Glossary of terms for thermal insulation of buildings

AS 3742-1990 Mineral wool thermal insulation - Batt and blanket
AS 4075-1993 Urea-formaldehyde foam thermal insulation - Installation requirements for in situ set foam
AS 3700 SUPP 1-2004 Masonry structures - Commentary (Supplement to AS 3700-2001)
AS 3999-1992 Thermal insulation of dwellings - Bulk insulation - Installation requirements
AS/NZS 4200.1:1994 Pliable building membranes and underlays Materials
AS 2462-1981 Cellulosic fibre thermal insulation
HB 63-1994 Home insulation in Australia - Recommended insulation levels for all States as per Australian Standard AS 2627.1
AS/NZS 4200.2:1994 Pliable building membranes and underlays Installation requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.